Cargando…

A High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS Experiment

The expected increase of the particle flux at the high luminosity phase of the LHC (HL-LHC) with instantaneous luminosities up to L ≃ 7.5 × 10³⁴ cm¯² s¯¹ will have a severe impact on the ATLAS detector performance. The pile-up is expected to increase on average to 200 interactions per bunch crossing...

Descripción completa

Detalles Bibliográficos
Autor principal: Schwartzman, Ariel
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:http://cds.cern.ch/record/2628311
_version_ 1780959160659083264
author Schwartzman, Ariel
author_facet Schwartzman, Ariel
author_sort Schwartzman, Ariel
collection CERN
description The expected increase of the particle flux at the high luminosity phase of the LHC (HL-LHC) with instantaneous luminosities up to L ≃ 7.5 × 10³⁴ cm¯² s¯¹ will have a severe impact on the ATLAS detector performance. The pile-up is expected to increase on average to 200 interactions per bunch crossing. The reconstruction and trigger performance for electrons, photons as well as jets and transverse missing energy will be severely degraded in the end-cap and forward region, where the liquid Argon based electromagnetic calorimeter has coarser granularity and the inner tracker has poorer momentum resolution compared to the central region. A High Granularity Timing Detector (HGTD) is proposed in front of the liquid Argon end-cap calorimeters for pile-up mitigation and for bunch per bunch luminosity measurements. This device should cover the pseudo-rapidity range of 2.4 to about 4.0. Two Silicon sensors double sided layers are foreseen to provide a precision timing information for minimum ionizing particle with a time resolution better than 50 pico-seconds per hit (i.e 30 pico-seconds per track) in order to assign the particle to the correct vertex. Each readout cell has a transverse size of 1.3 mm × 1.3 mm leading to a highly granular detector with about 3 millions of readout electronics channels. Low Gain Avalanche Detectors (LGAD) technology has been chosen as it provides an internal gain good enough to reach large signal over noise ratio needed for excellent time resolution. The requirements and overall specifications of the High Granular Timing Detector at the HL-LHC will be presented as well as the conceptual design. Most recent results on the main R&D will be discussed, with emphasis on the LGAD sensors (sensor optimisation as thickness, dead zone…., and radiation hardness) and ASIC. Beam test results of gain, timing resolution and efficiency will be also shown.
id cern-2628311
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling cern-26283112019-09-30T06:29:59Zhttp://cds.cern.ch/record/2628311engSchwartzman, ArielA High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS ExperimentParticle Physics - ExperimentThe expected increase of the particle flux at the high luminosity phase of the LHC (HL-LHC) with instantaneous luminosities up to L ≃ 7.5 × 10³⁴ cm¯² s¯¹ will have a severe impact on the ATLAS detector performance. The pile-up is expected to increase on average to 200 interactions per bunch crossing. The reconstruction and trigger performance for electrons, photons as well as jets and transverse missing energy will be severely degraded in the end-cap and forward region, where the liquid Argon based electromagnetic calorimeter has coarser granularity and the inner tracker has poorer momentum resolution compared to the central region. A High Granularity Timing Detector (HGTD) is proposed in front of the liquid Argon end-cap calorimeters for pile-up mitigation and for bunch per bunch luminosity measurements. This device should cover the pseudo-rapidity range of 2.4 to about 4.0. Two Silicon sensors double sided layers are foreseen to provide a precision timing information for minimum ionizing particle with a time resolution better than 50 pico-seconds per hit (i.e 30 pico-seconds per track) in order to assign the particle to the correct vertex. Each readout cell has a transverse size of 1.3 mm × 1.3 mm leading to a highly granular detector with about 3 millions of readout electronics channels. Low Gain Avalanche Detectors (LGAD) technology has been chosen as it provides an internal gain good enough to reach large signal over noise ratio needed for excellent time resolution. The requirements and overall specifications of the High Granular Timing Detector at the HL-LHC will be presented as well as the conceptual design. Most recent results on the main R&D will be discussed, with emphasis on the LGAD sensors (sensor optimisation as thickness, dead zone…., and radiation hardness) and ASIC. Beam test results of gain, timing resolution and efficiency will be also shown.ATL-LARG-SLIDE-2018-446oai:cds.cern.ch:26283112018-07-03
spellingShingle Particle Physics - Experiment
Schwartzman, Ariel
A High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS Experiment
title A High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS Experiment
title_full A High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS Experiment
title_fullStr A High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS Experiment
title_full_unstemmed A High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS Experiment
title_short A High-Granularity Timing Detector for the Phase-2 Upgrade of the ATLAS Experiment
title_sort high-granularity timing detector for the phase-2 upgrade of the atlas experiment
topic Particle Physics - Experiment
url http://cds.cern.ch/record/2628311
work_keys_str_mv AT schwartzmanariel ahighgranularitytimingdetectorforthephase2upgradeoftheatlasexperiment
AT schwartzmanariel highgranularitytimingdetectorforthephase2upgradeoftheatlasexperiment