Cargando…

Study of stability of gain and energy resolution for GEM detector in high rate operation

Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO 2 in 70/30 ratio and conventional NIM electronics. A strong 55 Fe X-ray source is used for this study. The novelty...

Descripción completa

Detalles Bibliográficos
Autores principales: Roy, S., Rudra, S., Shaw, S., Chatterjee, S., Chakraborty, S., Adak, R.P., Biswas, S., Das, S., Ghosh, S.K., Prasad, S.K., Raha, S.
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2018.10.060
http://cds.cern.ch/record/2628415
_version_ 1780959167747457024
author Roy, S.
Rudra, S.
Shaw, S.
Chatterjee, S.
Chakraborty, S.
Adak, R.P.
Biswas, S.
Das, S.
Ghosh, S.K.
Prasad, S.K.
Raha, S.
author_facet Roy, S.
Rudra, S.
Shaw, S.
Chatterjee, S.
Chakraborty, S.
Adak, R.P.
Biswas, S.
Das, S.
Ghosh, S.K.
Prasad, S.K.
Raha, S.
author_sort Roy, S.
collection CERN
description Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO 2 in 70/30 ratio and conventional NIM electronics. A strong 55 Fe X-ray source is used for this study. The novelty of this study is that for the stability test same source is used to irradiate the GEM chamber and to monitor the spectrum. The radiation is not collimated to a point but exposed to a larger area. Effect of temperature and pressure on these parameters are also studied. The detail method of measurement and the first test results are presented.
id cern-2628415
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling cern-26284152021-09-30T08:01:05Zdoi:10.1016/j.nima.2018.10.060http://cds.cern.ch/record/2628415engRoy, S.Rudra, S.Shaw, S.Chatterjee, S.Chakraborty, S.Adak, R.P.Biswas, S.Das, S.Ghosh, S.K.Prasad, S.K.Raha, S.Study of stability of gain and energy resolution for GEM detector in high rate operationphysics.ins-detDetectors and Experimental TechniquesStudy of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO 2 in 70/30 ratio and conventional NIM electronics. A strong 55 Fe X-ray source is used for this study. The novelty of this study is that for the stability test same source is used to irradiate the GEM chamber and to monitor the spectrum. The radiation is not collimated to a point but exposed to a larger area. Effect of temperature and pressure on these parameters are also studied. The detail method of measurement and the first test results are presented.Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A strong Fe$^{55}$ X-ray source is used for this study. The novelty of this study is that for the stability test same source is used to irradiate the GEM chamber and to monitor the spectrum. The radiation is not collimated to a point but exposed to a larger area. Effect of temperature and pressure on these parameters are also studied. The detail method of measurement and the first test results are presented in this article.arXiv:1804.02819oai:cds.cern.ch:26284152018-04-09
spellingShingle physics.ins-det
Detectors and Experimental Techniques
Roy, S.
Rudra, S.
Shaw, S.
Chatterjee, S.
Chakraborty, S.
Adak, R.P.
Biswas, S.
Das, S.
Ghosh, S.K.
Prasad, S.K.
Raha, S.
Study of stability of gain and energy resolution for GEM detector in high rate operation
title Study of stability of gain and energy resolution for GEM detector in high rate operation
title_full Study of stability of gain and energy resolution for GEM detector in high rate operation
title_fullStr Study of stability of gain and energy resolution for GEM detector in high rate operation
title_full_unstemmed Study of stability of gain and energy resolution for GEM detector in high rate operation
title_short Study of stability of gain and energy resolution for GEM detector in high rate operation
title_sort study of stability of gain and energy resolution for gem detector in high rate operation
topic physics.ins-det
Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2018.10.060
http://cds.cern.ch/record/2628415
work_keys_str_mv AT roys studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT rudras studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT shaws studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT chatterjees studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT chakrabortys studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT adakrp studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT biswass studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT dass studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT ghoshsk studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT prasadsk studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation
AT rahas studyofstabilityofgainandenergyresolutionforgemdetectorinhighrateoperation