Optical quality assurance of GEM foils

An analysis software was developed for the high aspect ratio optical scanning system in the Detector Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics syst...

Descripción completa

Detalles Bibliográficos
Autores principales: Hildén, T., Brücken, E., Heino, J., Kalliokoski, M., Karadzhinova, A., Lauhakangas, R., Tuominen, E., Turpeinen, R.
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2014.10.015
http://cds.cern.ch/record/2629421
_version_ 1780959272073428992
author Hildén, T.
Brücken, E.
Heino, J.
Kalliokoski, M.
Karadzhinova, A.
Lauhakangas, R.
Tuominen, E.
Turpeinen, R.
author_facet Hildén, T.
Brücken, E.
Heino, J.
Kalliokoski, M.
Karadzhinova, A.
Lauhakangas, R.
Tuominen, E.
Turpeinen, R.
author_sort Hildén, T.
collection CERN
description An analysis software was developed for the high aspect ratio optical scanning system in the Detector Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5μm and 0.3μm , respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain mapping of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes.
id cern-2629421
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling cern-26294212022-01-28T03:03:06Zdoi:10.1016/j.nima.2014.10.015doi:10.1016/j.nima.2014.10.015http://cds.cern.ch/record/2629421engHildén, T.Brücken, E.Heino, J.Kalliokoski, M.Karadzhinova, A.Lauhakangas, R.Tuominen, E.Turpeinen, R.Optical quality assurance of GEM foilsphysics.ins-detDetectors and Experimental TechniquesAn analysis software was developed for the high aspect ratio optical scanning system in the Detector Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5μm and 0.3μm , respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain mapping of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes.An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5 {\mu}m and 0.3 {\mu}m, respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain mapping of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes.arXiv:1704.06691oai:cds.cern.ch:26294212017-04-21
spellingShingle physics.ins-det
Detectors and Experimental Techniques
Hildén, T.
Brücken, E.
Heino, J.
Kalliokoski, M.
Karadzhinova, A.
Lauhakangas, R.
Tuominen, E.
Turpeinen, R.
Optical quality assurance of GEM foils
title Optical quality assurance of GEM foils
title_full Optical quality assurance of GEM foils
title_fullStr Optical quality assurance of GEM foils
title_full_unstemmed Optical quality assurance of GEM foils
title_short Optical quality assurance of GEM foils
title_sort optical quality assurance of gem foils
topic physics.ins-det
Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2014.10.015
https://dx.doi.org/10.1016/j.nima.2014.10.015
http://cds.cern.ch/record/2629421
work_keys_str_mv AT hildent opticalqualityassuranceofgemfoils
AT bruckene opticalqualityassuranceofgemfoils
AT heinoj opticalqualityassuranceofgemfoils
AT kalliokoskim opticalqualityassuranceofgemfoils
AT karadzhinovaa opticalqualityassuranceofgemfoils
AT lauhakangasr opticalqualityassuranceofgemfoils
AT tuominene opticalqualityassuranceofgemfoils
AT turpeinenr opticalqualityassuranceofgemfoils