Cargando…
Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes,...
Autores principales: | Babicz, M., Bagby, L., Baibussinov, B., Bellini, V., Bonesini, M., Braggiotti, A., Centro, S., Cervi, T., Cocco, A.G., Falcone, A., Farnese, C., Fava, A., Fichera, F., Gibin, D., Guglielmi, A., Kose, U., Mazza, R., Menegolli, A., Meng, G., Montanari, C., Nessi, M., Picchi, P., Pietropaolo, F., Prata, M.C., Rappoldi, A., Raselli, G.L., Rossella, M., Rubbia, C., Sala, P., Scaramelli, A., Sergiampietri, F., Spanu, M., Torti, M., Tortorici, F., Varanini, F., Ventura, S., Vignoli, C., Zani, A. |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/13/10/P10030 http://cds.cern.ch/record/2634094 |
Ejemplares similares
-
Timing properties of Hamamatsu R5912-MOD photomultiplier tube for the ICARUS T600 light detection system
por: Babicz, Marta, et al.
Publicado: (2018) -
Linearity and saturation properties of Hamamatsu R5912-MOD photomultiplier tube for the ICARUS T600 light detection system
por: Babicz, Marta, et al.
Publicado: (2019) -
Test and characterization of 20 pre-series hamamatsu R5916-MOD photomultiplier tubes for the ICARUS T600 detector
por: Raselli, G L, et al.
Publicado: (2017) -
Design and implementation of the new scintillation light detection system of ICARUS T600
por: Ali-Mohammadzadeh, B., et al.
Publicado: (2020) -
New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system
por: Bagby, L., et al.
Publicado: (2018)