Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements

Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Particularly important are the decays of the Higgs boson resulting in electromagnetic particles in the final state, as well as the searches for v...

Descripción completa

Detalles Bibliográficos
Autor principal: Cipriani, Marco
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.321.0084
http://cds.cern.ch/record/2637093
_version_ 1780959918452375552
author Cipriani, Marco
author_facet Cipriani, Marco
author_sort Cipriani, Marco
collection CERN
description Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Particularly important are the decays of the Higgs boson resulting in electromagnetic particles in the final state, as well as the searches for very high mass resonances decaying into energetic photons or electrons. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented values, using 25 ns bunch spacing. High pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms, to maintain the best possible performance in these more challenging conditions. The energy response of the detector must be precisely calibrated and monitored to achieve and maintain the excellent performance obtained in Run I in terms of energy scale and resolution. A dedicated calibration of each detector channel is performed with physics events exploiting electrons from W and Z boson decays, photons from pi0/eta decays, and from the azimuthally symmetric energy distribution of minimum bias events. This talk describes the calibration strategies and the performance of the CMS ECAL throughout Run II and its role in precision physics measurements with CMS involving electrons and photons.
id cern-2637093
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling cern-26370932019-10-15T15:28:33Zdoi:10.22323/1.321.0084http://cds.cern.ch/record/2637093engCipriani, MarcoPerformance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurementsDetectors and Experimental TechniquesMany physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Particularly important are the decays of the Higgs boson resulting in electromagnetic particles in the final state, as well as the searches for very high mass resonances decaying into energetic photons or electrons. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented values, using 25 ns bunch spacing. High pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms, to maintain the best possible performance in these more challenging conditions. The energy response of the detector must be precisely calibrated and monitored to achieve and maintain the excellent performance obtained in Run I in terms of energy scale and resolution. A dedicated calibration of each detector channel is performed with physics events exploiting electrons from W and Z boson decays, photons from pi0/eta decays, and from the azimuthally symmetric energy distribution of minimum bias events. This talk describes the calibration strategies and the performance of the CMS ECAL throughout Run II and its role in precision physics measurements with CMS involving electrons and photons.CMS-CR-2018-162oai:cds.cern.ch:26370932018-08-14
spellingShingle Detectors and Experimental Techniques
Cipriani, Marco
Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements
title Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements
title_full Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements
title_fullStr Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements
title_full_unstemmed Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements
title_short Performance of the CMS electromagnetic calorimeter during the LHC Run II and its role in precision physics measurements
title_sort performance of the cms electromagnetic calorimeter during the lhc run ii and its role in precision physics measurements
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.22323/1.321.0084
http://cds.cern.ch/record/2637093
work_keys_str_mv AT ciprianimarco performanceofthecmselectromagneticcalorimeterduringthelhcruniianditsroleinprecisionphysicsmeasurements