Cargando…
Test of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Board
Ultra Fast Silicon Detectors (UFSD) are sensors optimized for timing measurements employing a thin multiplication layer to increase the output signal. A multipurpose read-out board hosting a low-cost, low-power fast amplifier was designed at the University of Kansas and tested at the European Organi...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2017.04.032 http://cds.cern.ch/record/2644151 |
_version_ | 1780960348917989376 |
---|---|
author | Minafra, Nicola Al Ghoul, Hussein Arcidiacono, Roberta Cartiglia, Nicolo Forthomme, Laurent Mulargia, Roberto Obertino, Maria Royon, Christophe |
author_facet | Minafra, Nicola Al Ghoul, Hussein Arcidiacono, Roberta Cartiglia, Nicolo Forthomme, Laurent Mulargia, Roberto Obertino, Maria Royon, Christophe |
author_sort | Minafra, Nicola |
collection | CERN |
description | Ultra Fast Silicon Detectors (UFSD) are sensors optimized for timing measurements employing a thin multiplication layer to increase the output signal. A multipurpose read-out board hosting a low-cost, low-power fast amplifier was designed at the University of Kansas and tested at the European Organization for Nuclear Research (CERN) using a 180 GeV pion beam. The amplifier has been designed to read out a wide range of detectors and it was optimized in this test for the UFSD output signal. In this paper we report the results of the experimental tests using 50 $\rm{\mu m}$ thick UFSD with a sensitive area of 1.4 $\rm{mm^2}$. A timing precision below 30 ps was achieved. |
id | cern-2644151 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | cern-26441512021-05-03T20:28:17Zdoi:10.1016/j.nima.2017.04.032http://cds.cern.ch/record/2644151engMinafra, NicolaAl Ghoul, HusseinArcidiacono, RobertaCartiglia, NicoloForthomme, LaurentMulargia, RobertoObertino, MariaRoyon, ChristopheTest of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Boardphysics.ins-detDetectors and Experimental TechniquesUltra Fast Silicon Detectors (UFSD) are sensors optimized for timing measurements employing a thin multiplication layer to increase the output signal. A multipurpose read-out board hosting a low-cost, low-power fast amplifier was designed at the University of Kansas and tested at the European Organization for Nuclear Research (CERN) using a 180 GeV pion beam. The amplifier has been designed to read out a wide range of detectors and it was optimized in this test for the UFSD output signal. In this paper we report the results of the experimental tests using 50 $\rm{\mu m}$ thick UFSD with a sensitive area of 1.4 $\rm{mm^2}$. A timing precision below 30 ps was achieved.Ultra Fast Silicon Detectors (UFSD) are sensors optimized for timing measurements employing a thin multiplication layer to increase the output signal. A multipurpose read-out board hosting a low-cost, low-power fast amplifier was designed at the University of Kansas and tested at the European Organization for Nuclear Research (CERN) using a 180 GeV pion beam. The amplifier has been designed to read out a wide range of detectors and it was optimized in this test for the UFSD output signal. In this paper we report the results of the experimental tests using 50 µm thick UFSD with a sensitive area of 1.4mm2 . A timing precision below 30 ps was achieved.arXiv:1704.05298oai:cds.cern.ch:26441512017-04-18 |
spellingShingle | physics.ins-det Detectors and Experimental Techniques Minafra, Nicola Al Ghoul, Hussein Arcidiacono, Roberta Cartiglia, Nicolo Forthomme, Laurent Mulargia, Roberto Obertino, Maria Royon, Christophe Test of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Board |
title | Test of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Board |
title_full | Test of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Board |
title_fullStr | Test of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Board |
title_full_unstemmed | Test of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Board |
title_short | Test of Ultra Fast Silicon Detectors for Picosecond Time Measurements with a New Multipurpose Read-Out Board |
title_sort | test of ultra fast silicon detectors for picosecond time measurements with a new multipurpose read-out board |
topic | physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2017.04.032 http://cds.cern.ch/record/2644151 |
work_keys_str_mv | AT minafranicola testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard AT alghoulhussein testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard AT arcidiaconoroberta testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard AT cartiglianicolo testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard AT forthommelaurent testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard AT mulargiaroberto testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard AT obertinomaria testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard AT royonchristophe testofultrafastsilicondetectorsforpicosecondtimemeasurementswithanewmultipurposereadoutboard |