Cargando…
Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade
The Phase I Upgrade of the CMS Hadron Forward Calorimeters was completed during the Extended Year End Technical Stop of 2016 - 2017. In the framework of the upgrade, the front-end electronics were replaced and the PMT boxes were reworked to implement two-channel readout in order to exploit the benef...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/NSSMIC.2018.8824334 http://cds.cern.ch/record/2645762 |
_version_ | 1780960452337991680 |
---|---|
author | Bilki, Burak Onel, Yasar Gulmez, Erhan |
author_facet | Bilki, Burak Onel, Yasar Gulmez, Erhan |
author_sort | Bilki, Burak |
collection | CERN |
description | The Phase I Upgrade of the CMS Hadron Forward Calorimeters was completed during the Extended Year End Technical Stop of 2016 - 2017. In the framework of the upgrade, the front-end electronics were replaced and the PMT boxes were reworked to implement two-channel readout in order to exploit the benefits of the multi-anode PMTs. The new PMTs with two channel readout allow background tagging and signal recovery. In addition, the front-end electronics implement a 6-bit TDC to provide an additional handle to eliminate the background. The Hadron Forward Calorimeters were commissioned and operated successfully in 2017 data taking period. Here we describe the details and the components of the upgrade, and discuss the operational experience with the Phase I Upgrade. |
id | cern-2645762 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
record_format | invenio |
spelling | cern-26457622020-01-21T14:02:45Zdoi:10.1109/NSSMIC.2018.8824334http://cds.cern.ch/record/2645762engBilki, BurakOnel, YasarGulmez, ErhanOperational Experience with the CMS Hadron Forward Calorimeters Phase I UpgradeDetectors and Experimental TechniquesThe Phase I Upgrade of the CMS Hadron Forward Calorimeters was completed during the Extended Year End Technical Stop of 2016 - 2017. In the framework of the upgrade, the front-end electronics were replaced and the PMT boxes were reworked to implement two-channel readout in order to exploit the benefits of the multi-anode PMTs. The new PMTs with two channel readout allow background tagging and signal recovery. In addition, the front-end electronics implement a 6-bit TDC to provide an additional handle to eliminate the background. The Hadron Forward Calorimeters were commissioned and operated successfully in 2017 data taking period. Here we describe the details and the components of the upgrade, and discuss the operational experience with the Phase I Upgrade.CMS-CR-2018-296oai:cds.cern.ch:26457622018-10-19 |
spellingShingle | Detectors and Experimental Techniques Bilki, Burak Onel, Yasar Gulmez, Erhan Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade |
title | Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade |
title_full | Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade |
title_fullStr | Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade |
title_full_unstemmed | Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade |
title_short | Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade |
title_sort | operational experience with the cms hadron forward calorimeters phase i upgrade |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/NSSMIC.2018.8824334 http://cds.cern.ch/record/2645762 |
work_keys_str_mv | AT bilkiburak operationalexperiencewiththecmshadronforwardcalorimetersphaseiupgrade AT onelyasar operationalexperiencewiththecmshadronforwardcalorimetersphaseiupgrade AT gulmezerhan operationalexperiencewiththecmshadronforwardcalorimetersphaseiupgrade |