Cargando…

Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade

The Phase I Upgrade of the CMS Hadron Forward Calorimeters was completed during the Extended Year End Technical Stop of 2016 - 2017. In the framework of the upgrade, the front-end electronics were replaced and the PMT boxes were reworked to implement two-channel readout in order to exploit the benef...

Descripción completa

Detalles Bibliográficos
Autores principales: Bilki, Burak, Onel, Yasar, Gulmez, Erhan
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1109/NSSMIC.2018.8824334
http://cds.cern.ch/record/2645762
_version_ 1780960452337991680
author Bilki, Burak
Onel, Yasar
Gulmez, Erhan
author_facet Bilki, Burak
Onel, Yasar
Gulmez, Erhan
author_sort Bilki, Burak
collection CERN
description The Phase I Upgrade of the CMS Hadron Forward Calorimeters was completed during the Extended Year End Technical Stop of 2016 - 2017. In the framework of the upgrade, the front-end electronics were replaced and the PMT boxes were reworked to implement two-channel readout in order to exploit the benefits of the multi-anode PMTs. The new PMTs with two channel readout allow background tagging and signal recovery. In addition, the front-end electronics implement a 6-bit TDC to provide an additional handle to eliminate the background. The Hadron Forward Calorimeters were commissioned and operated successfully in 2017 data taking period. Here we describe the details and the components of the upgrade, and discuss the operational experience with the Phase I Upgrade.
id cern-2645762
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling cern-26457622020-01-21T14:02:45Zdoi:10.1109/NSSMIC.2018.8824334http://cds.cern.ch/record/2645762engBilki, BurakOnel, YasarGulmez, ErhanOperational Experience with the CMS Hadron Forward Calorimeters Phase I UpgradeDetectors and Experimental TechniquesThe Phase I Upgrade of the CMS Hadron Forward Calorimeters was completed during the Extended Year End Technical Stop of 2016 - 2017. In the framework of the upgrade, the front-end electronics were replaced and the PMT boxes were reworked to implement two-channel readout in order to exploit the benefits of the multi-anode PMTs. The new PMTs with two channel readout allow background tagging and signal recovery. In addition, the front-end electronics implement a 6-bit TDC to provide an additional handle to eliminate the background. The Hadron Forward Calorimeters were commissioned and operated successfully in 2017 data taking period. Here we describe the details and the components of the upgrade, and discuss the operational experience with the Phase I Upgrade.CMS-CR-2018-296oai:cds.cern.ch:26457622018-10-19
spellingShingle Detectors and Experimental Techniques
Bilki, Burak
Onel, Yasar
Gulmez, Erhan
Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade
title Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade
title_full Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade
title_fullStr Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade
title_full_unstemmed Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade
title_short Operational Experience with the CMS Hadron Forward Calorimeters Phase I Upgrade
title_sort operational experience with the cms hadron forward calorimeters phase i upgrade
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/NSSMIC.2018.8824334
http://cds.cern.ch/record/2645762
work_keys_str_mv AT bilkiburak operationalexperiencewiththecmshadronforwardcalorimetersphaseiupgrade
AT onelyasar operationalexperiencewiththecmshadronforwardcalorimetersphaseiupgrade
AT gulmezerhan operationalexperiencewiththecmshadronforwardcalorimetersphaseiupgrade