Cargando…
CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal.
The existing Compact Muon Solenoid (CMS) Endcap Hadron Calorimeters (HE) have been in operation for several years and contributed substantially to the success of the CMS Physics Program. The High Luminosity Large Hadron Collider (HL-LHC) performance criteria, however, require a re-examination of the...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2649424 |
_version_ | 1780960735111675904 |
---|---|
author | Ershov, Yuri Golutvin, Igor Kashpydai, Omak Kulikova, Tatiana Lavrenov, Pavel Orlov, A.N Postnov, Artem |
author_facet | Ershov, Yuri Golutvin, Igor Kashpydai, Omak Kulikova, Tatiana Lavrenov, Pavel Orlov, A.N Postnov, Artem |
author_sort | Ershov, Yuri |
collection | CERN |
description | The existing Compact Muon Solenoid (CMS) Endcap Hadron Calorimeters (HE) have been in operation for several years and contributed substantially to the success of the CMS Physics Program. The High Luminosity Large Hadron Collider (HL-LHC) performance criteria, however, require a re-examination of the ability of the detector active material and electronics to meet the requirements of 3000 fb$^{-1}$ [1, 2]. Based on these studies, CMS proposes the replacement of the Endcap Calorimeters, which cover the region of pseudorapidity $1.5<\mid \eta \mid<3.0$, with a new High-Granularity sampling Calorimeter (HGC). The current HE calorimeters are proposed to be converted to the Backing Hadron Calorimeter (BH). For the BH, the base line mechanical design, scintillator design and segmentation, and optical readout scheme must be defined by the end of 2016. Also upgraded Endcap design must provide the accessibility of BH and easy scintillators (megatiles) replacement [3]. This can be achieved by the adding of a new element "Trays Skirt". A possible design of this element is presented. |
id | cern-2649424 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | cern-26494242019-09-30T06:29:59Zhttp://cds.cern.ch/record/2649424engErshov, YuriGolutvin, IgorKashpydai, OmakKulikova, TatianaLavrenov, PavelOrlov, A.NPostnov, ArtemCMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal.Detectors and Experimental TechniquesThe existing Compact Muon Solenoid (CMS) Endcap Hadron Calorimeters (HE) have been in operation for several years and contributed substantially to the success of the CMS Physics Program. The High Luminosity Large Hadron Collider (HL-LHC) performance criteria, however, require a re-examination of the ability of the detector active material and electronics to meet the requirements of 3000 fb$^{-1}$ [1, 2]. Based on these studies, CMS proposes the replacement of the Endcap Calorimeters, which cover the region of pseudorapidity $1.5<\mid \eta \mid<3.0$, with a new High-Granularity sampling Calorimeter (HGC). The current HE calorimeters are proposed to be converted to the Backing Hadron Calorimeter (BH). For the BH, the base line mechanical design, scintillator design and segmentation, and optical readout scheme must be defined by the end of 2016. Also upgraded Endcap design must provide the accessibility of BH and easy scintillators (megatiles) replacement [3]. This can be achieved by the adding of a new element "Trays Skirt". A possible design of this element is presented.CMS-NOTE-2018-004CERN-CMS-NOTE-2018-004oai:cds.cern.ch:26494242016-04-14 |
spellingShingle | Detectors and Experimental Techniques Ershov, Yuri Golutvin, Igor Kashpydai, Omak Kulikova, Tatiana Lavrenov, Pavel Orlov, A.N Postnov, Artem CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal. |
title | CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal. |
title_full | CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal. |
title_fullStr | CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal. |
title_full_unstemmed | CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal. |
title_short | CMS Endcap Calorimeter for HL-LHC design. Trays Skirt for Backing HE Endcap Calorimeter accessibility. Technical proposal. |
title_sort | cms endcap calorimeter for hl-lhc design. trays skirt for backing he endcap calorimeter accessibility. technical proposal. |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2649424 |
work_keys_str_mv | AT ershovyuri cmsendcapcalorimeterforhllhcdesigntraysskirtforbackingheendcapcalorimeteraccessibilitytechnicalproposal AT golutvinigor cmsendcapcalorimeterforhllhcdesigntraysskirtforbackingheendcapcalorimeteraccessibilitytechnicalproposal AT kashpydaiomak cmsendcapcalorimeterforhllhcdesigntraysskirtforbackingheendcapcalorimeteraccessibilitytechnicalproposal AT kulikovatatiana cmsendcapcalorimeterforhllhcdesigntraysskirtforbackingheendcapcalorimeteraccessibilitytechnicalproposal AT lavrenovpavel cmsendcapcalorimeterforhllhcdesigntraysskirtforbackingheendcapcalorimeteraccessibilitytechnicalproposal AT orlovan cmsendcapcalorimeterforhllhcdesigntraysskirtforbackingheendcapcalorimeteraccessibilitytechnicalproposal AT postnovartem cmsendcapcalorimeterforhllhcdesigntraysskirtforbackingheendcapcalorimeteraccessibilitytechnicalproposal |