Cargando…
Evaluation of different readout systems with the FE-I4-based IBL stave
This bachelor thesis deals with the tuning of the readout chip "FE-I4B" used in the innermost layer of the Pixel detector. Two different readout systems, YARR (Yet Another Rapid Readout) and RCE (Reconfiggurable Cluster Element), are evaluated with regard to the FE-I4B tuning results. Thre...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2655507 |
_version_ | 1780961175617404928 |
---|---|
author | Stratmann, Maren |
author_facet | Stratmann, Maren |
author_sort | Stratmann, Maren |
collection | CERN |
description | This bachelor thesis deals with the tuning of the readout chip "FE-I4B" used in the innermost layer of the Pixel detector. Two different readout systems, YARR (Yet Another Rapid Readout) and RCE (Reconfiggurable Cluster Element), are evaluated with regard to the FE-I4B tuning results. Three front-end chips of modules mounted on a production IBL stave are used for the tests. The tunings with both readout systems show comparable results. Both YARR and RCE reached good values for a target threshold of 3,000 electrons and a target ToT of 10 with an injected charge of 16,000 electrons, which is a parameter combination commonly used. RCE showed more stable results after tunings with very low target parameters, such as a threshold of 1,500 e− or a target ToT of 5. For these tunings, YARR occasionally returned threshold values more than 500 e− above the target value. |
id | cern-2655507 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | cern-26555072019-09-30T06:29:59Zhttp://cds.cern.ch/record/2655507engStratmann, MarenEvaluation of different readout systems with the FE-I4-based IBL staveDetectors and Experimental TechniquesThis bachelor thesis deals with the tuning of the readout chip "FE-I4B" used in the innermost layer of the Pixel detector. Two different readout systems, YARR (Yet Another Rapid Readout) and RCE (Reconfiggurable Cluster Element), are evaluated with regard to the FE-I4B tuning results. Three front-end chips of modules mounted on a production IBL stave are used for the tests. The tunings with both readout systems show comparable results. Both YARR and RCE reached good values for a target threshold of 3,000 electrons and a target ToT of 10 with an injected charge of 16,000 electrons, which is a parameter combination commonly used. RCE showed more stable results after tunings with very low target parameters, such as a threshold of 1,500 e− or a target ToT of 5. For these tunings, YARR occasionally returned threshold values more than 500 e− above the target value.CERN-THESIS-2018-344oai:cds.cern.ch:26555072019-02-01T16:21:08Z |
spellingShingle | Detectors and Experimental Techniques Stratmann, Maren Evaluation of different readout systems with the FE-I4-based IBL stave |
title | Evaluation of different readout systems with the FE-I4-based IBL stave |
title_full | Evaluation of different readout systems with the FE-I4-based IBL stave |
title_fullStr | Evaluation of different readout systems with the FE-I4-based IBL stave |
title_full_unstemmed | Evaluation of different readout systems with the FE-I4-based IBL stave |
title_short | Evaluation of different readout systems with the FE-I4-based IBL stave |
title_sort | evaluation of different readout systems with the fe-i4-based ibl stave |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2655507 |
work_keys_str_mv | AT stratmannmaren evaluationofdifferentreadoutsystemswiththefei4basediblstave |