Cargando…

Radiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear Colliders

For the design of the electromagnetic calorimeter (ECal) of a future linear collider the required dynamic range for the possible readout options and the expected radiation doses have to be known. High energy electromagnetic showers are simulated to estimate the required dynamic range for a scintilla...

Descripción completa

Detalles Bibliográficos
Autor principal: Sailer, Andre
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:http://cds.cern.ch/record/2668318
_version_ 1780962162701762560
author Sailer, Andre
author_facet Sailer, Andre
author_sort Sailer, Andre
collection CERN
description For the design of the electromagnetic calorimeter (ECal) of a future linear collider the required dynamic range for the possible readout options and the expected radiation doses have to be known. High energy electromagnetic showers are simulated to estimate the required dynamic range for a scintillator-pad based ECal read out with silicon photo-multipliers. For 1.5\,TeV photons energy deposits corresponding to $10^4$ and more minimum ionising particles in pads of 10\,mm × 10\,mm and 20\,mm × 20\,mm are found. From simulations of the main beam-induced backgrounds a maximal total ionising dose of a few Gray per year and 1-MeV-neutron equivalent fluxes around $10^{10}$ per square centimetre and year are found in the ECal of the 3 TeV CLIC and 1 TeV ILC experiments.
id cern-2668318
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling cern-26683182019-09-30T06:29:59Zhttp://cds.cern.ch/record/2668318engSailer, AndreRadiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear CollidersAccelerators and Storage RingsFor the design of the electromagnetic calorimeter (ECal) of a future linear collider the required dynamic range for the possible readout options and the expected radiation doses have to be known. High energy electromagnetic showers are simulated to estimate the required dynamic range for a scintillator-pad based ECal read out with silicon photo-multipliers. For 1.5\,TeV photons energy deposits corresponding to $10^4$ and more minimum ionising particles in pads of 10\,mm × 10\,mm and 20\,mm × 20\,mm are found. From simulations of the main beam-induced backgrounds a maximal total ionising dose of a few Gray per year and 1-MeV-neutron equivalent fluxes around $10^{10}$ per square centimetre and year are found in the ECal of the 3 TeV CLIC and 1 TeV ILC experiments.CLICdp-Note-2019-001oai:cds.cern.ch:26683182019
spellingShingle Accelerators and Storage Rings
Sailer, Andre
Radiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear Colliders
title Radiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear Colliders
title_full Radiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear Colliders
title_fullStr Radiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear Colliders
title_full_unstemmed Radiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear Colliders
title_short Radiation Levels and Saturation Effects in the Electromagnetic Calorimeter of Future Linear Colliders
title_sort radiation levels and saturation effects in the electromagnetic calorimeter of future linear colliders
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2668318
work_keys_str_mv AT sailerandre radiationlevelsandsaturationeffectsintheelectromagneticcalorimeteroffuturelinearcolliders