Synchrotron radiation reflections in the CLIC Beam Delivery System

Synchrotron radiation (SR) reflection is an important issue for future linear colliders. High fluxes of SR might impact the performance of the detector, through irradiation of the forward luminosity and beam quality calorimeters or of the innermost layers of the vertex detector. The photon reflectio...

Descripción completa

Detalles Bibliográficos
Autores principales: Arominski, Dominik, Latina, Andrea, Sailer, Andre, Schulte, Daniel
Lenguaje:eng
Publicado: JACoW 2019
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2019-WEPTS104
https://dx.doi.org/10.1088/1742-6596/1350/1/012123
http://cds.cern.ch/record/2678470
_version_ 1780962850835005440
author Arominski, Dominik
Latina, Andrea
Sailer, Andre
Schulte, Daniel
author_facet Arominski, Dominik
Latina, Andrea
Sailer, Andre
Schulte, Daniel
author_sort Arominski, Dominik
collection CERN
description Synchrotron radiation (SR) reflection is an important issue for future linear colliders. High fluxes of SR might impact the performance of the detector, through irradiation of the forward luminosity and beam quality calorimeters or of the innermost layers of the vertex detector. The photon reflections depend on the beam pipe apertures’ size, their shape, and materials used with various surface roughness. In this work, we present a study of SR including reflection for the 380 GeV and 3 TeV beam parameters and optics of the Compact Linear Collider’s Final Focus System. The simulations of the SR reflections using the Synrad+ software are presented and the impact on the detector is discussed.
id cern-2678470
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
publisher JACoW
record_format invenio
spelling cern-26784702021-02-09T10:05:42Zdoi:10.18429/JACoW-IPAC2019-WEPTS104doi:10.1088/1742-6596/1350/1/012123http://cds.cern.ch/record/2678470engArominski, DominikLatina, AndreaSailer, AndreSchulte, DanielSynchrotron radiation reflections in the CLIC Beam Delivery SystemParticle Physics - ExperimentSynchrotron radiation (SR) reflection is an important issue for future linear colliders. High fluxes of SR might impact the performance of the detector, through irradiation of the forward luminosity and beam quality calorimeters or of the innermost layers of the vertex detector. The photon reflections depend on the beam pipe apertures’ size, their shape, and materials used with various surface roughness. In this work, we present a study of SR including reflection for the 380 GeV and 3 TeV beam parameters and optics of the Compact Linear Collider’s Final Focus System. The simulations of the SR reflections using the Synrad+ software are presented and the impact on the detector is discussed.JACoWCLICdp-Conf-2019-007oai:cds.cern.ch:26784702019
spellingShingle Particle Physics - Experiment
Arominski, Dominik
Latina, Andrea
Sailer, Andre
Schulte, Daniel
Synchrotron radiation reflections in the CLIC Beam Delivery System
title Synchrotron radiation reflections in the CLIC Beam Delivery System
title_full Synchrotron radiation reflections in the CLIC Beam Delivery System
title_fullStr Synchrotron radiation reflections in the CLIC Beam Delivery System
title_full_unstemmed Synchrotron radiation reflections in the CLIC Beam Delivery System
title_short Synchrotron radiation reflections in the CLIC Beam Delivery System
title_sort synchrotron radiation reflections in the clic beam delivery system
topic Particle Physics - Experiment
url https://dx.doi.org/10.18429/JACoW-IPAC2019-WEPTS104
https://dx.doi.org/10.1088/1742-6596/1350/1/012123
http://cds.cern.ch/record/2678470
work_keys_str_mv AT arominskidominik synchrotronradiationreflectionsintheclicbeamdeliverysystem
AT latinaandrea synchrotronradiationreflectionsintheclicbeamdeliverysystem
AT sailerandre synchrotronradiationreflectionsintheclicbeamdeliverysystem
AT schultedaniel synchrotronradiationreflectionsintheclicbeamdeliverysystem