Cargando…
Long-term monitoring of delivered luminosity & calibration stability in CMS
Lumi days 2019 presentation. Indico https://indico.cern.ch/event/813285/timetable/ Uncertainty of the delivered luminosity in years 2017 and 2018 due to stability and linearity is discussed. CMS emittance scans are employed to monitor stability of the absolute calibration and to derive non-linearit...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2681803 |
_version_ | 1780963057599512576 |
---|---|
author | CMS Collaboration |
author_facet | CMS Collaboration |
author_sort | CMS Collaboration |
collection | CERN |
description | Lumi days 2019 presentation. Indico https://indico.cern.ch/event/813285/timetable/
Uncertainty of the delivered luminosity in years 2017 and 2018 due to stability and linearity is discussed. CMS emittance scans are employed to monitor stability of the absolute calibration and to derive non-linearity correction. They are very powerful and employed from 2017 on the regular bases. Also mu-scans as alternative for linearity cross check are presented. |
id | cern-2681803 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | cern-26818032019-09-30T06:29:59Zhttp://cds.cern.ch/record/2681803engCMS CollaborationLong-term monitoring of delivered luminosity & calibration stability in CMSDetectors and Experimental TechniquesLumi days 2019 presentation. Indico https://indico.cern.ch/event/813285/timetable/ Uncertainty of the delivered luminosity in years 2017 and 2018 due to stability and linearity is discussed. CMS emittance scans are employed to monitor stability of the absolute calibration and to derive non-linearity correction. They are very powerful and employed from 2017 on the regular bases. Also mu-scans as alternative for linearity cross check are presented.CMS-DP-2019-016CERN-CMS-DP-2019-016oai:cds.cern.ch:26818032019-06-06 |
spellingShingle | Detectors and Experimental Techniques CMS Collaboration Long-term monitoring of delivered luminosity & calibration stability in CMS |
title | Long-term monitoring of delivered luminosity & calibration stability in CMS |
title_full | Long-term monitoring of delivered luminosity & calibration stability in CMS |
title_fullStr | Long-term monitoring of delivered luminosity & calibration stability in CMS |
title_full_unstemmed | Long-term monitoring of delivered luminosity & calibration stability in CMS |
title_short | Long-term monitoring of delivered luminosity & calibration stability in CMS |
title_sort | long-term monitoring of delivered luminosity & calibration stability in cms |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2681803 |
work_keys_str_mv | AT cmscollaboration longtermmonitoringofdeliveredluminositycalibrationstabilityincms |