Cargando…

Aging Studies on SWPC and Triple GEM Detectors

This report considers an aging analysis on the triple gas electron multiplier (GEM) technology, that will be installed through projects GE1/1, GE2/1 and ME0 on the CMS muon system. Prior to installation it is important to consider the aging effects caused by radiation on these detectors. Hence, both...

Descripción completa

Detalles Bibliográficos
Autor principal: Michael, Andreas
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:http://cds.cern.ch/record/2686178
_version_ 1780963532175572992
author Michael, Andreas
author_facet Michael, Andreas
author_sort Michael, Andreas
collection CERN
description This report considers an aging analysis on the triple gas electron multiplier (GEM) technology, that will be installed through projects GE1/1, GE2/1 and ME0 on the CMS muon system. Prior to installation it is important to consider the aging effects caused by radiation on these detectors. Hence, both a GEM and a single wire chamber (SWPC) detector are irradiated with X-ray (Cadmium-109) and Alpha (Americium-241) sources. Rapid aging is achieved through the outgassing of pollutants, increasing the number of radicals and subsequently production of polymers which cause aging. During the whole of the irradiation period, the SWPC collected a charge of 14 mC/cm and the GEM collected a charge of 60mC/cm2. The measured gain is corrected using environmental parameters and along with the energy resolution of the chambers are used to show the aging effects on the detectors. Finally, the gain degradation of the SWPC is 15%, with the GEM showing no degradation at all. These results prove their resilience and pave the way for multiple rapid aging tests that must be carried through for understanding the complicated process of aging.
id cern-2686178
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling cern-26861782019-09-30T06:29:59Zhttp://cds.cern.ch/record/2686178engMichael, AndreasAging Studies on SWPC and Triple GEM DetectorsParticle Physics - ExperimentThis report considers an aging analysis on the triple gas electron multiplier (GEM) technology, that will be installed through projects GE1/1, GE2/1 and ME0 on the CMS muon system. Prior to installation it is important to consider the aging effects caused by radiation on these detectors. Hence, both a GEM and a single wire chamber (SWPC) detector are irradiated with X-ray (Cadmium-109) and Alpha (Americium-241) sources. Rapid aging is achieved through the outgassing of pollutants, increasing the number of radicals and subsequently production of polymers which cause aging. During the whole of the irradiation period, the SWPC collected a charge of 14 mC/cm and the GEM collected a charge of 60mC/cm2. The measured gain is corrected using environmental parameters and along with the energy resolution of the chambers are used to show the aging effects on the detectors. Finally, the gain degradation of the SWPC is 15%, with the GEM showing no degradation at all. These results prove their resilience and pave the way for multiple rapid aging tests that must be carried through for understanding the complicated process of aging.CERN-STUDENTS-Note-2019-036oai:cds.cern.ch:26861782019-08-09
spellingShingle Particle Physics - Experiment
Michael, Andreas
Aging Studies on SWPC and Triple GEM Detectors
title Aging Studies on SWPC and Triple GEM Detectors
title_full Aging Studies on SWPC and Triple GEM Detectors
title_fullStr Aging Studies on SWPC and Triple GEM Detectors
title_full_unstemmed Aging Studies on SWPC and Triple GEM Detectors
title_short Aging Studies on SWPC and Triple GEM Detectors
title_sort aging studies on swpc and triple gem detectors
topic Particle Physics - Experiment
url http://cds.cern.ch/record/2686178
work_keys_str_mv AT michaelandreas agingstudiesonswpcandtriplegemdetectors