An alternative energy calibration method for Timepix3

The purpose of this project is to perform an energy calibration method on the Timepix3 detector based on test pulse and source data. The Timepix3 acquisition mode allows the counter to work as a timer and measure the time of arrival (ToA) and time over threshold (ToT) for every incoming particle in...

Descripción completa

Detalles Bibliográficos
Autor principal: Perez, Maria Laura
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:http://cds.cern.ch/record/2686194
_version_ 1780963532817301504
author Perez, Maria Laura
author_facet Perez, Maria Laura
author_sort Perez, Maria Laura
collection CERN
description The purpose of this project is to perform an energy calibration method on the Timepix3 detector based on test pulse and source data. The Timepix3 acquisition mode allows the counter to work as a timer and measure the time of arrival (ToA) and time over threshold (ToT) for every incoming particle in a pixel in a data driven readout. As this implies a high volume of data, processing algorithms such as clustering and charge collection efficiency studies have to be taken into account. The energy measurements can be extracted from the ToT data, and converted to energy by performing a mixed calibration using test pulse data and $\gamma$ sources. Test pulse calibration shows an offset with respect to the source calibration, which is explained and corrected in order to be able to fuse them together, as source calibration values cannot be obtained properly at low energies due to experimental limitations. Compared with the factory calibration performed by Advacam, the source-test-pulse (STP) calibration shows higher accuracy for low energies when tested on Ca XRF measurements and slightly lower accuracy for higher energies, tested on Ag, Sn and Gd XRF measurements. The drift is due to temperature changes in the setup, meaning that a more stable setup could potentially increase the method's accuracy for energy measurements.
id cern-2686194
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling cern-26861942019-09-30T06:29:59Zhttp://cds.cern.ch/record/2686194engPerez, Maria LauraAn alternative energy calibration method for Timepix3Detectors and Experimental TechniquesThe purpose of this project is to perform an energy calibration method on the Timepix3 detector based on test pulse and source data. The Timepix3 acquisition mode allows the counter to work as a timer and measure the time of arrival (ToA) and time over threshold (ToT) for every incoming particle in a pixel in a data driven readout. As this implies a high volume of data, processing algorithms such as clustering and charge collection efficiency studies have to be taken into account. The energy measurements can be extracted from the ToT data, and converted to energy by performing a mixed calibration using test pulse data and $\gamma$ sources. Test pulse calibration shows an offset with respect to the source calibration, which is explained and corrected in order to be able to fuse them together, as source calibration values cannot be obtained properly at low energies due to experimental limitations. Compared with the factory calibration performed by Advacam, the source-test-pulse (STP) calibration shows higher accuracy for low energies when tested on Ca XRF measurements and slightly lower accuracy for higher energies, tested on Ag, Sn and Gd XRF measurements. The drift is due to temperature changes in the setup, meaning that a more stable setup could potentially increase the method's accuracy for energy measurements.CERN-STUDENTS-Note-2019-040oai:cds.cern.ch:26861942019-08-08
spellingShingle Detectors and Experimental Techniques
Perez, Maria Laura
An alternative energy calibration method for Timepix3
title An alternative energy calibration method for Timepix3
title_full An alternative energy calibration method for Timepix3
title_fullStr An alternative energy calibration method for Timepix3
title_full_unstemmed An alternative energy calibration method for Timepix3
title_short An alternative energy calibration method for Timepix3
title_sort alternative energy calibration method for timepix3
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2686194
work_keys_str_mv AT perezmarialaura analternativeenergycalibrationmethodfortimepix3
AT perezmarialaura alternativeenergycalibrationmethodfortimepix3