Cargando…

Assessment performance and emittance measurements tests of Basler digital camera vs. the standard BTV system at CLEAR.

In this report, the new digital system installed at CLEAR was analyzed. To measure its efficiency, beam Emittance and Twiss parameters were tested by comparing the results of the Basler digital camera with the results of the traditional BTV system. The new digital system presented better results reg...

Descripción completa

Detalles Bibliográficos
Autor principal: Cocha Toapaxi, Carlos Eduardo
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:http://cds.cern.ch/record/2686221
Descripción
Sumario:In this report, the new digital system installed at CLEAR was analyzed. To measure its efficiency, beam Emittance and Twiss parameters were tested by comparing the results of the Basler digital camera with the results of the traditional BTV system. The new digital system presented better results regarding the quality and resolution of the images obtained. In addition, this digital system presented a smaller standard error of the mean beam size, which led to a lower final error of the emittance and Twiss parameters. Besides, Monte Carlos was used to propagate the errors. In general, these results appear to be the same as with the BTV camera, especially in current ranges near and equidistant to the minimum point of the parabola obtained after the Quadrupole Scan. In the horizontal plane, beam size values for current ranges far from the minimum point tend to create slightly different parabolas in both cameras, which leads to different results. In the vertical plane, this issue was not observed. The main responsible seems to be a bad alignment in the installation of the Basler digital camera. In the horizontal plane, a normalized emittance of 17.163 $\pm$ 0.14 mm.mrad and 13.91 ± 0.18 mm.mrad and in the vertical plane were obtained for the Basler camera. On the other hand, a normalized emittance of 17.167 $\pm$ 0.12 mm.mrad in the horizontal plane and 13.84 $\pm$ 0.077 mm.mrad in the vertical plane for the BTV camera were obtained. All these calculation were done with an energy of 200 MeV.