Cargando…
Setup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKE
We describe a method to overcome the triggering jitter of a streak camera to obtain less noisy images of a self-modulated proton bunch over long time scales (~ 400 ps to ns) with the time resolution (~ 1 ps) of the short time scale images (73 ps). We also determine that this method, using a referenc...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1742-6596/1596/1/012006 http://cds.cern.ch/record/2703566 |
_version_ | 1780964638243946496 |
---|---|
author | Batsch, Fabian |
author_facet | Batsch, Fabian |
author_sort | Batsch, Fabian |
collection | CERN |
description | We describe a method to overcome the triggering jitter of a streak camera to obtain less noisy images of a self-modulated proton bunch over long time scales (~ 400 ps to ns) with the time resolution (~ 1 ps) of the short time scale images (73 ps). We also determine that this method, using a reference laser pulse with a variable delay, leads to the determination of the time delay between the ionizing laser pulse and the reference pulse with an error of 0.6 ps (rms). |
id | cern-2703566 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | cern-27035662023-07-13T03:29:00Zdoi:10.1088/1742-6596/1596/1/012006http://cds.cern.ch/record/2703566engBatsch, FabianSetup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKEphysics.acc-phAccelerators and Storage Ringsphysics.ins-detDetectors and Experimental TechniquesWe describe a method to overcome the triggering jitter of a streak camera to obtain less noisy images of a self-modulated proton bunch over long time scales (~ 400 ps to ns) with the time resolution (~ 1 ps) of the short time scale images (73 ps). We also determine that this method, using a reference laser pulse with a variable delay, leads to the determination of the time delay between the ionizing laser pulse and the reference pulse with an error of 0.6 ps (rms).We describe a method to overcome the triggering jitter of a streak camera to obtain less noisy images of a self-modulated proton bunch over long time scales ($\sim$ 400 ps to ns) with the time resolution ($\sim$ 1 ps) of the short time scale images (73 ps). We also determine that this method, using a reference laser pulse with a variable delay, leads to the determination of the time delay between the ionizing laser pulse and the reference pulse with an error of 0.6 ps (rms).arXiv:1911.12201oai:cds.cern.ch:27035662019-11-27 |
spellingShingle | physics.acc-ph Accelerators and Storage Rings physics.ins-det Detectors and Experimental Techniques Batsch, Fabian Setup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKE |
title | Setup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKE |
title_full | Setup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKE |
title_fullStr | Setup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKE |
title_full_unstemmed | Setup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKE |
title_short | Setup and Characteristics of a Timing Reference Signal with sub-ps Accuracy for AWAKE |
title_sort | setup and characteristics of a timing reference signal with sub-ps accuracy for awake |
topic | physics.acc-ph Accelerators and Storage Rings physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1742-6596/1596/1/012006 http://cds.cern.ch/record/2703566 |
work_keys_str_mv | AT batschfabian setupandcharacteristicsofatimingreferencesignalwithsubpsaccuracyforawake |