Cargando…

FLUKA-Geant4 comparison for the muon flux experiment in the H4 beamline

The FLUKA - Geant4 comparison for the the muon flux experiment is reported. The experiment was performed in 2018 on the H4 400 GeV/c proton beamline to measure the muon flux emanating from a SHiP replica target. Good agreement between the two Monte Carlo simulations was found, in the low momentum and...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahdida, Claudia Christina, Casolino, Mirkoantonio, Dijkstra, Hans, Froeschl, Robert, Van Herwijnen, Eric, Ruf, Thomas
Publicado: 2019
Materias:
Acceso en línea:http://cds.cern.ch/record/2705389
_version_ 1780964809173368832
author Ahdida, Claudia Christina
Casolino, Mirkoantonio
Dijkstra, Hans
Froeschl, Robert
Van Herwijnen, Eric
Ruf, Thomas
author_facet Ahdida, Claudia Christina
Casolino, Mirkoantonio
Dijkstra, Hans
Froeschl, Robert
Van Herwijnen, Eric
Ruf, Thomas
author_sort Ahdida, Claudia Christina
collection CERN
description The FLUKA - Geant4 comparison for the the muon flux experiment is reported. The experiment was performed in 2018 on the H4 400 GeV/c proton beamline to measure the muon flux emanating from a SHiP replica target. Good agreement between the two Monte Carlo simulations was found, in the low momentum and low transverse momentum range the agreement is at the level of 20%, while in the tails the disagreement is at maximum of a factor ∼3. These results suggest to reduce the safety factor for future BDF/SHiP facility radiation calculations from 5 (old recommended value) to 3 (new value).
id cern-2705389
institution Organización Europea para la Investigación Nuclear
publishDate 2019
record_format invenio
spelling cern-27053892019-12-19T20:57:26Zhttp://cds.cern.ch/record/2705389Ahdida, Claudia ChristinaCasolino, MirkoantonioDijkstra, HansFroeschl, RobertVan Herwijnen, EricRuf, ThomasFLUKA-Geant4 comparison for the muon flux experiment in the H4 beamlineAccelerators and Storage RingsThe FLUKA - Geant4 comparison for the the muon flux experiment is reported. The experiment was performed in 2018 on the H4 400 GeV/c proton beamline to measure the muon flux emanating from a SHiP replica target. Good agreement between the two Monte Carlo simulations was found, in the low momentum and low transverse momentum range the agreement is at the level of 20%, while in the tails the disagreement is at maximum of a factor ∼3. These results suggest to reduce the safety factor for future BDF/SHiP facility radiation calculations from 5 (old recommended value) to 3 (new value).CERN-SHiP-NOTE-2019-005oai:cds.cern.ch:27053892019
spellingShingle Accelerators and Storage Rings
Ahdida, Claudia Christina
Casolino, Mirkoantonio
Dijkstra, Hans
Froeschl, Robert
Van Herwijnen, Eric
Ruf, Thomas
FLUKA-Geant4 comparison for the muon flux experiment in the H4 beamline
title FLUKA-Geant4 comparison for the muon flux experiment in the H4 beamline
title_full FLUKA-Geant4 comparison for the muon flux experiment in the H4 beamline
title_fullStr FLUKA-Geant4 comparison for the muon flux experiment in the H4 beamline
title_full_unstemmed FLUKA-Geant4 comparison for the muon flux experiment in the H4 beamline
title_short FLUKA-Geant4 comparison for the muon flux experiment in the H4 beamline
title_sort fluka-geant4 comparison for the muon flux experiment in the h4 beamline
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2705389
work_keys_str_mv AT ahdidaclaudiachristina flukageant4comparisonforthemuonfluxexperimentintheh4beamline
AT casolinomirkoantonio flukageant4comparisonforthemuonfluxexperimentintheh4beamline
AT dijkstrahans flukageant4comparisonforthemuonfluxexperimentintheh4beamline
AT froeschlrobert flukageant4comparisonforthemuonfluxexperimentintheh4beamline
AT vanherwijneneric flukageant4comparisonforthemuonfluxexperimentintheh4beamline
AT rufthomas flukageant4comparisonforthemuonfluxexperimentintheh4beamline