Cargando…
MD1787 - LHC TDI tune shift measurement at injection
This report summarizes the results of the backup activity performed after cancellation of the MD1787. This MD was originally conceived to measure the instability growth rate versus chromaticity and damper settings at injections energy in the LHC, but, due to an RFQ issue in the Linac2 followed by a...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2712341 |
_version_ | 1780965276615966720 |
---|---|
author | Amorim, David Biancacci, Nicolo Carbajo Perez, David Carver, Lee Robert Metral, Elias Rijoff, Tatiana Libera Salvant, Benoit Soderen, Martin Valuch, Daniel |
author_facet | Amorim, David Biancacci, Nicolo Carbajo Perez, David Carver, Lee Robert Metral, Elias Rijoff, Tatiana Libera Salvant, Benoit Soderen, Martin Valuch, Daniel |
author_sort | Amorim, David |
collection | CERN |
description | This report summarizes the results of the backup activity performed after cancellation of the MD1787. This MD was originally conceived to measure the instability growth rate versus chromaticity and damper settings at injections energy in the LHC, but, due to an RFQ issue in the Linac2 followed by an issue with the LHC cryogenic system, the original plan could not be executed. As a short backup activity on the available time given by the daylight saving on 30th October 2016 and the kind cooperation with other LHC MD users, it was decided to characterize with beam the TDI impedance. |
id | cern-2712341 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | cern-27123412020-03-06T22:49:15Zhttp://cds.cern.ch/record/2712341engAmorim, DavidBiancacci, NicoloCarbajo Perez, DavidCarver, Lee RobertMetral, EliasRijoff, Tatiana LiberaSalvant, BenoitSoderen, MartinValuch, DanielMD1787 - LHC TDI tune shift measurement at injection Accelerators and Storage RingsThis report summarizes the results of the backup activity performed after cancellation of the MD1787. This MD was originally conceived to measure the instability growth rate versus chromaticity and damper settings at injections energy in the LHC, but, due to an RFQ issue in the Linac2 followed by an issue with the LHC cryogenic system, the original plan could not be executed. As a short backup activity on the available time given by the daylight saving on 30th October 2016 and the kind cooperation with other LHC MD users, it was decided to characterize with beam the TDI impedance. CERN-ACC-NOTE-2020-0015oai:cds.cern.ch:27123412019-01-30 |
spellingShingle | Accelerators and Storage Rings Amorim, David Biancacci, Nicolo Carbajo Perez, David Carver, Lee Robert Metral, Elias Rijoff, Tatiana Libera Salvant, Benoit Soderen, Martin Valuch, Daniel MD1787 - LHC TDI tune shift measurement at injection |
title | MD1787 - LHC TDI tune shift measurement at injection |
title_full | MD1787 - LHC TDI tune shift measurement at injection |
title_fullStr | MD1787 - LHC TDI tune shift measurement at injection |
title_full_unstemmed | MD1787 - LHC TDI tune shift measurement at injection |
title_short | MD1787 - LHC TDI tune shift measurement at injection |
title_sort | md1787 - lhc tdi tune shift measurement at injection |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/2712341 |
work_keys_str_mv | AT amorimdavid md1787lhctdituneshiftmeasurementatinjection AT biancaccinicolo md1787lhctdituneshiftmeasurementatinjection AT carbajoperezdavid md1787lhctdituneshiftmeasurementatinjection AT carverleerobert md1787lhctdituneshiftmeasurementatinjection AT metralelias md1787lhctdituneshiftmeasurementatinjection AT rijofftatianalibera md1787lhctdituneshiftmeasurementatinjection AT salvantbenoit md1787lhctdituneshiftmeasurementatinjection AT soderenmartin md1787lhctdituneshiftmeasurementatinjection AT valuchdaniel md1787lhctdituneshiftmeasurementatinjection |