Cargando…
CMS Tracker Performance results for full Run 2 Legacy reprocessing
During the LHC Long Shutdown 2, the CMS experiment started a collaboration-wide effort to re-calibrate the data and optimize the simulation, reconstruction and analysis software in order to reprocess the data collected during LHC Run 2 with uniform software and detector calibrations (Legacy processi...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2713208 |
_version_ | 1780965324003213312 |
---|---|
author | CMS Collaboration |
author_facet | CMS Collaboration |
author_sort | CMS Collaboration |
collection | CERN |
description | During the LHC Long Shutdown 2, the CMS experiment started a collaboration-wide effort to re-calibrate the data and optimize the simulation, reconstruction and analysis software in order to reprocess the data collected during LHC Run 2 with uniform software and detector calibrations (Legacy processing). \\
This note collects performance results of the tracker detector alignment obtained using the updated Legacy software and calibration for the data collected by CMS during the three years period 2016, 2017 and 2018, and corresponding to an integrated luminosity of about 140/fb. The results include the comparison of the performance of the updated conditions to the one of the alignment and calibration used during data-taking, as well as the one derived at the end of each data-taking year. |
id | cern-2713208 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27132082020-05-04T21:38:30Zhttp://cds.cern.ch/record/2713208engCMS CollaborationCMS Tracker Performance results for full Run 2 Legacy reprocessingDetectors and Experimental TechniquesDuring the LHC Long Shutdown 2, the CMS experiment started a collaboration-wide effort to re-calibrate the data and optimize the simulation, reconstruction and analysis software in order to reprocess the data collected during LHC Run 2 with uniform software and detector calibrations (Legacy processing). \\ This note collects performance results of the tracker detector alignment obtained using the updated Legacy software and calibration for the data collected by CMS during the three years period 2016, 2017 and 2018, and corresponding to an integrated luminosity of about 140/fb. The results include the comparison of the performance of the updated conditions to the one of the alignment and calibration used during data-taking, as well as the one derived at the end of each data-taking year.CMS-DP-2020-012CERN-CMS-DP-2020-012oai:cds.cern.ch:27132082020-02-27 |
spellingShingle | Detectors and Experimental Techniques CMS Collaboration CMS Tracker Performance results for full Run 2 Legacy reprocessing |
title | CMS Tracker Performance results for full Run 2 Legacy reprocessing |
title_full | CMS Tracker Performance results for full Run 2 Legacy reprocessing |
title_fullStr | CMS Tracker Performance results for full Run 2 Legacy reprocessing |
title_full_unstemmed | CMS Tracker Performance results for full Run 2 Legacy reprocessing |
title_short | CMS Tracker Performance results for full Run 2 Legacy reprocessing |
title_sort | cms tracker performance results for full run 2 legacy reprocessing |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2713208 |
work_keys_str_mv | AT cmscollaboration cmstrackerperformanceresultsforfullrun2legacyreprocessing |