Cargando…

CMS Tracker Performance results for full Run 2 Legacy reprocessing

During the LHC Long Shutdown 2, the CMS experiment started a collaboration-wide effort to re-calibrate the data and optimize the simulation, reconstruction and analysis software in order to reprocess the data collected during LHC Run 2 with uniform software and detector calibrations (Legacy processi...

Descripción completa

Detalles Bibliográficos
Autor principal: CMS Collaboration
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:http://cds.cern.ch/record/2713208
_version_ 1780965324003213312
author CMS Collaboration
author_facet CMS Collaboration
author_sort CMS Collaboration
collection CERN
description During the LHC Long Shutdown 2, the CMS experiment started a collaboration-wide effort to re-calibrate the data and optimize the simulation, reconstruction and analysis software in order to reprocess the data collected during LHC Run 2 with uniform software and detector calibrations (Legacy processing). \\ This note collects performance results of the tracker detector alignment obtained using the updated Legacy software and calibration for the data collected by CMS during the three years period 2016, 2017 and 2018, and corresponding to an integrated luminosity of about 140/fb. The results include the comparison of the performance of the updated conditions to the one of the alignment and calibration used during data-taking, as well as the one derived at the end of each data-taking year.
id cern-2713208
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27132082020-05-04T21:38:30Zhttp://cds.cern.ch/record/2713208engCMS CollaborationCMS Tracker Performance results for full Run 2 Legacy reprocessingDetectors and Experimental TechniquesDuring the LHC Long Shutdown 2, the CMS experiment started a collaboration-wide effort to re-calibrate the data and optimize the simulation, reconstruction and analysis software in order to reprocess the data collected during LHC Run 2 with uniform software and detector calibrations (Legacy processing). \\ This note collects performance results of the tracker detector alignment obtained using the updated Legacy software and calibration for the data collected by CMS during the three years period 2016, 2017 and 2018, and corresponding to an integrated luminosity of about 140/fb. The results include the comparison of the performance of the updated conditions to the one of the alignment and calibration used during data-taking, as well as the one derived at the end of each data-taking year.CMS-DP-2020-012CERN-CMS-DP-2020-012oai:cds.cern.ch:27132082020-02-27
spellingShingle Detectors and Experimental Techniques
CMS Collaboration
CMS Tracker Performance results for full Run 2 Legacy reprocessing
title CMS Tracker Performance results for full Run 2 Legacy reprocessing
title_full CMS Tracker Performance results for full Run 2 Legacy reprocessing
title_fullStr CMS Tracker Performance results for full Run 2 Legacy reprocessing
title_full_unstemmed CMS Tracker Performance results for full Run 2 Legacy reprocessing
title_short CMS Tracker Performance results for full Run 2 Legacy reprocessing
title_sort cms tracker performance results for full run 2 legacy reprocessing
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2713208
work_keys_str_mv AT cmscollaboration cmstrackerperformanceresultsforfullrun2legacyreprocessing