Cargando…

Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up

This Detector Performance Summary shows results from detailed temperature studies on a mock-up of a half-layer of the CMS Phase-1 pixel detector using realistic heat loads and identical CO$_{2}$ cooling circuits. From the measured temperature distribution the consequences on leakage currents have be...

Descripción completa

Detalles Bibliográficos
Autor principal: CMS Collaboration
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:http://cds.cern.ch/record/2714879
_version_ 1780965414146146304
author CMS Collaboration
author_facet CMS Collaboration
author_sort CMS Collaboration
collection CERN
description This Detector Performance Summary shows results from detailed temperature studies on a mock-up of a half-layer of the CMS Phase-1 pixel detector using realistic heat loads and identical CO$_{2}$ cooling circuits. From the measured temperature distribution the consequences on leakage currents have been evaluated.
id cern-2714879
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27148792020-04-07T19:03:49Zhttp://cds.cern.ch/record/2714879engCMS CollaborationExpected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-UpDetectors and Experimental TechniquesThis Detector Performance Summary shows results from detailed temperature studies on a mock-up of a half-layer of the CMS Phase-1 pixel detector using realistic heat loads and identical CO$_{2}$ cooling circuits. From the measured temperature distribution the consequences on leakage currents have been evaluated.CMS-DP-2020-008CERN-CMS-DP-2020-008oai:cds.cern.ch:27148792020-02-10
spellingShingle Detectors and Experimental Techniques
CMS Collaboration
Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up
title Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up
title_full Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up
title_fullStr Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up
title_full_unstemmed Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up
title_short Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up
title_sort expected leakage current distribution in bpix based on measurements in a thermal mock-up
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2714879
work_keys_str_mv AT cmscollaboration expectedleakagecurrentdistributioninbpixbasedonmeasurementsinathermalmockup