Expected Leakage Current Distribution in BPix based on Measurements in a Thermal Mock-Up
This Detector Performance Summary shows results from detailed temperature studies on a mock-up of a half-layer of the CMS Phase-1 pixel detector using realistic heat loads and identical CO$_{2}$ cooling circuits. From the measured temperature distribution the consequences on leakage currents have be...
Autor principal: | CMS Collaboration |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2714879 |
Ejemplares similares
-
Preshower bulk leakage current measurements
por: CMS Collaboration
Publicado: (2012) -
Measurement and modelling of the leakage current and depletion voltage in Phase-1 Forward Pixel
por: CMS Collaboration
Publicado: (2021) -
Development of the CMS Phase-1 Pixel Online Monitoring System and the Distribution and Evolution of Temperatures and Sensor Leakage Currents
por: CMS Collaboration
Publicado: (2020) -
BCM Detector Performance Plots showing radiation damage to diamond sensors based on leakage current measurements and fluka simulations
por: CMS Collaboration
Publicado: (2012) -
Stability and quench propagation velocities measurements on the "Racetrack" Mock-up of ATLAS toroid coil
por: Juster, F P, et al.