Cargando…

Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-II

Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Excellent energy resolution is crucial for studies of Higgs boson decays with electromagnetic particles in the final state, as well as searches f...

Descripción completa

Detalles Bibliográficos
Autor principal: Kuo, Chia-Ming
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/15/06/C06001
http://cds.cern.ch/record/2715622
_version_ 1780965438617812992
author Kuo, Chia-Ming
author_facet Kuo, Chia-Ming
author_sort Kuo, Chia-Ming
collection CERN
description Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Excellent energy resolution is crucial for studies of Higgs boson decays with electromagnetic particles in the final state, as well as searches for very high mass resonances decaying to energetic photons or electrons. The CMS electromagnetic calorimeter (ECAL) is a fundamental instrument for these analyses and its energy resolution is crucial for the Higgs boson mass measurement. Recently the energy response of the calorimeter has been precisely calibrated exploiting the full Run-II data, aiming at a legacy reprocessing of the data. A dedicated calibration of each detector channel has been performed with physics events exploiting electrons from W and Z boson decays, and photons from $\pi^0/\eta$ decays. This talk presents the calibration strategies that have been implemented and the excellent performance achieved by the CMS ECAL with the ultimate calibration of Run-II data, in terms of energy scale stability and energy resolution.
id cern-2715622
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27156222022-11-17T14:33:01Zdoi:10.1088/1748-0221/15/06/C06001http://cds.cern.ch/record/2715622engKuo, Chia-MingCalibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-IIDetectors and Experimental TechniquesMany physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. Excellent energy resolution is crucial for studies of Higgs boson decays with electromagnetic particles in the final state, as well as searches for very high mass resonances decaying to energetic photons or electrons. The CMS electromagnetic calorimeter (ECAL) is a fundamental instrument for these analyses and its energy resolution is crucial for the Higgs boson mass measurement. Recently the energy response of the calorimeter has been precisely calibrated exploiting the full Run-II data, aiming at a legacy reprocessing of the data. A dedicated calibration of each detector channel has been performed with physics events exploiting electrons from W and Z boson decays, and photons from $\pi^0/\eta$ decays. This talk presents the calibration strategies that have been implemented and the excellent performance achieved by the CMS ECAL with the ultimate calibration of Run-II data, in terms of energy scale stability and energy resolution.CMS-CR-2020-074oai:cds.cern.ch:27156222020-03-01
spellingShingle Detectors and Experimental Techniques
Kuo, Chia-Ming
Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-II
title Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-II
title_full Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-II
title_fullStr Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-II
title_full_unstemmed Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-II
title_short Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run-II
title_sort calibration and performance of the cms electromagnetic calorimeter in lhc run-ii
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/15/06/C06001
http://cds.cern.ch/record/2715622
work_keys_str_mv AT kuochiaming calibrationandperformanceofthecmselectromagneticcalorimeterinlhcrunii