Cargando…
The factorization bias in the Van der Meer method: Run 2 experiences at the CMS experiment
The luminosity measurement of the CMS experiment at the CERN LHC is calibrated with Van der Meer (VdM) scans. A bias occurs in the VdM method due to the assumption of transversely factorizable proton densities of the LHC beams. Here, the different methods applied in Run 2 to estimate the size of the...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2715626 |
_version_ | 1780965439503859712 |
---|---|
author | Knolle, Joscha |
author_facet | Knolle, Joscha |
author_sort | Knolle, Joscha |
collection | CERN |
description | The luminosity measurement of the CMS experiment at the CERN LHC is calibrated with Van der Meer (VdM) scans. A bias occurs in the VdM method due to the assumption of transversely factorizable proton densities of the LHC beams. Here, the different methods applied in Run 2 to estimate the size of the factorization bias are reported. The beam-imaging method reconstructs the transverse proton densities from beam-imaging scans. Additional methods exploit offset scans, analyze the evolution of the measured luminous region, and evaluate diagonal scans. |
id | cern-2715626 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | cern-27156262020-04-20T20:01:30Zhttp://cds.cern.ch/record/2715626engKnolle, JoschaThe factorization bias in the Van der Meer method: Run 2 experiences at the CMS experimentDetectors and Experimental TechniquesThe luminosity measurement of the CMS experiment at the CERN LHC is calibrated with Van der Meer (VdM) scans. A bias occurs in the VdM method due to the assumption of transversely factorizable proton densities of the LHC beams. Here, the different methods applied in Run 2 to estimate the size of the factorization bias are reported. The beam-imaging method reconstructs the transverse proton densities from beam-imaging scans. Additional methods exploit offset scans, analyze the evolution of the measured luminous region, and evaluate diagonal scans.CMS-CR-2019-129oai:cds.cern.ch:27156262019-09-04 |
spellingShingle | Detectors and Experimental Techniques Knolle, Joscha The factorization bias in the Van der Meer method: Run 2 experiences at the CMS experiment |
title | The factorization bias in the Van der Meer method: Run 2 experiences at the CMS experiment |
title_full | The factorization bias in the Van der Meer method: Run 2 experiences at the CMS experiment |
title_fullStr | The factorization bias in the Van der Meer method: Run 2 experiences at the CMS experiment |
title_full_unstemmed | The factorization bias in the Van der Meer method: Run 2 experiences at the CMS experiment |
title_short | The factorization bias in the Van der Meer method: Run 2 experiences at the CMS experiment |
title_sort | factorization bias in the van der meer method: run 2 experiences at the cms experiment |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2715626 |
work_keys_str_mv | AT knollejoscha thefactorizationbiasinthevandermeermethodrun2experiencesatthecmsexperiment AT knollejoscha factorizationbiasinthevandermeermethodrun2experiencesatthecmsexperiment |