Cargando…
CALICE SiW ECAL - Development and test of the chip-on-board PCB solution
The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International Linear Collider (ILC). Prototypes for this type of detector are d...
Autor principal: | |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
JINST
2020
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/15/05/C05001 http://cds.cern.ch/record/2717330 |
_version_ | 1780965610035871744 |
---|---|
author | Irles, Adrian |
author_facet | Irles, Adrian |
author_sort | Irles, Adrian |
collection | CERN |
description | The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International Linear Collider (ILC). Prototypes for this type of detector are developed within the CALICE Collaboration. This contribution reports on the development of an ultra-thin PCB called Chip-on-Board (COB) that is equipped with wirebonded ASICs and pixelated silicon wafers. This set will form the basic unit of detection of the SiW ECAL. It will favour the design of an ultra compact calorimeter since these boards feature a thickness of 1.2 mm to be compared with the 3 mm of the default solution variant using ASICs in BGA packaging. We report also on the first results obtained with the COB boards on a beam test at DESY. |
format | info:eu-repo/semantics/article |
id | cern-2717330 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
publisher | JINST |
record_format | invenio |
spelling | cern-27173302023-08-09T03:03:08Z doi:10.1088/1748-0221/15/05/C05001 http://cds.cern.ch/record/2717330 eng Irles, Adrian CALICE SiW ECAL - Development and test of the chip-on-board PCB solution Particle Physics - Experiment Detectors and Experimental Techniques 14: Infrastructure for advanced calorimeters The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International Linear Collider (ILC). Prototypes for this type of detector are developed within the CALICE Collaboration. This contribution reports on the development of an ultra-thin PCB called Chip-on-Board (COB) that is equipped with wirebonded ASICs and pixelated silicon wafers. This set will form the basic unit of detection of the SiW ECAL. It will favour the design of an ultra compact calorimeter since these boards feature a thickness of 1.2 mm to be compared with the 3 mm of the default solution variant using ASICs in BGA packaging. We report also on the first results obtained with the COB boards on a beam test at DESY. The highly granular silicon-tungsten electromagnetic calorimeter (SiW ECAL) is the reference design of the ECAL for the International Large Detector (ILD) concept, one of the two detector concepts proposed for the future International Linear Collider (ILC). Prototypes for this type of detector are developed within the CALICE Collaboration. This contribution reports on the development of an ultra-thin PCB called Chip-on-Board (COB) that is equipped with wirebonded ASICs and pixelated silicon wafers. This set will form the basic unit of detection of the SiW ECAL. It will favour the design of an ultra compact calorimeter since these boards feature a thickness of 1.2 mm to be compared with the 3 mm of the default solution variant using ASICs in BGA packaging. We report also on the first results obtained with the COB boards on a beam test at DESY. info:eu-repo/grantAgreement/EC/FP7/654168 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2717330 JINST JINST, 05 (2020) pp. C05001 2020-04-27 |
spellingShingle | Particle Physics - Experiment Detectors and Experimental Techniques 14: Infrastructure for advanced calorimeters Irles, Adrian CALICE SiW ECAL - Development and test of the chip-on-board PCB solution |
title | CALICE SiW ECAL - Development and test of the chip-on-board PCB solution |
title_full | CALICE SiW ECAL - Development and test of the chip-on-board PCB solution |
title_fullStr | CALICE SiW ECAL - Development and test of the chip-on-board PCB solution |
title_full_unstemmed | CALICE SiW ECAL - Development and test of the chip-on-board PCB solution |
title_short | CALICE SiW ECAL - Development and test of the chip-on-board PCB solution |
title_sort | calice siw ecal - development and test of the chip-on-board pcb solution |
topic | Particle Physics - Experiment Detectors and Experimental Techniques 14: Infrastructure for advanced calorimeters |
url | https://dx.doi.org/10.1088/1748-0221/15/05/C05001 http://cds.cern.ch/record/2717330 http://cds.cern.ch/record/2717330 |
work_keys_str_mv | AT irlesadrian calicesiwecaldevelopmentandtestofthechiponboardpcbsolution |