A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres

A portable test-bench has been developed to enable the real-time measurement of radiation-induced absorption in scintillating and wavelength-shifting fibres. Such fibres are typically used in the readout of fibre calorimeters or scintillating tiles such as those used in some hadron calorimeters. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Hobson, Peter, Smith, David R.
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:http://cds.cern.ch/record/2718828
_version_ 1780965665089257472
author Hobson, Peter
Smith, David R.
author_facet Hobson, Peter
Smith, David R.
author_sort Hobson, Peter
collection CERN
description A portable test-bench has been developed to enable the real-time measurement of radiation-induced absorption in scintillating and wavelength-shifting fibres. Such fibres are typically used in the readout of fibre calorimeters or scintillating tiles such as those used in some hadron calorimeters. The testbench has been designed to be used in a range of facilities, such as 60Co irradiators or high-intensity test beam facilities, and can accommodate fibres with length up to 300 mm and diameter greater than 1.0 mm. The test fibres are illuminated using a combined deuterium and halogen light source focussed onto the end of the fibre with a 0.25 NA radiation-tolerant quartz lens. The light transmitted by the fibre is collected by an identical lens and measured as a function of wavelength with a linear charge-coupled device spectrometer covering a wavelength range of 190 to 850 nm. We present the design of the test-bench, and studies of the systematic errors arising from the components. We measured induced absorbance in the fibres tested and determined the major systematic error to be the stability of the light source. Planned enhancements to the test-bench are discussed.
format info:eu-repo/semantics/article
id cern-2718828
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27188282020-05-25T21:44:20Z http://cds.cern.ch/record/2718828 eng Hobson, Peter Smith, David R. A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres Detectors and Experimental Techniques 14: Infrastructure for advanced calorimeters A portable test-bench has been developed to enable the real-time measurement of radiation-induced absorption in scintillating and wavelength-shifting fibres. Such fibres are typically used in the readout of fibre calorimeters or scintillating tiles such as those used in some hadron calorimeters. The testbench has been designed to be used in a range of facilities, such as 60Co irradiators or high-intensity test beam facilities, and can accommodate fibres with length up to 300 mm and diameter greater than 1.0 mm. The test fibres are illuminated using a combined deuterium and halogen light source focussed onto the end of the fibre with a 0.25 NA radiation-tolerant quartz lens. The light transmitted by the fibre is collected by an identical lens and measured as a function of wavelength with a linear charge-coupled device spectrometer covering a wavelength range of 190 to 850 nm. We present the design of the test-bench, and studies of the systematic errors arising from the components. We measured induced absorbance in the fibres tested and determined the major systematic error to be the stability of the light source. Planned enhancements to the test-bench are discussed. info:eu-repo/grantAgreement/EC/FP7/654168 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2718828 2020
spellingShingle Detectors and Experimental Techniques
14: Infrastructure for advanced calorimeters
Hobson, Peter
Smith, David R.
A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres
title A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres
title_full A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres
title_fullStr A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres
title_full_unstemmed A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres
title_short A portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres
title_sort portable test-bench for real-time radiation damage measurements in scintillating and wavelength-shifting fibres
topic Detectors and Experimental Techniques
14: Infrastructure for advanced calorimeters
url http://cds.cern.ch/record/2718828
http://cds.cern.ch/record/2718828
work_keys_str_mv AT hobsonpeter aportabletestbenchforrealtimeradiationdamagemeasurementsinscintillatingandwavelengthshiftingfibres
AT smithdavidr aportabletestbenchforrealtimeradiationdamagemeasurementsinscintillatingandwavelengthshiftingfibres
AT hobsonpeter portabletestbenchforrealtimeradiationdamagemeasurementsinscintillatingandwavelengthshiftingfibres
AT smithdavidr portabletestbenchforrealtimeradiationdamagemeasurementsinscintillatingandwavelengthshiftingfibres