Cargando…
A Light Calibration System for the ProtoDUNE-DP Detector
A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber (LAr TPC) currently being installed at the Neutrino Platform at CERN. The PDS is based on 36 8-inch ph...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
JINST
2020
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/14/04/T04001 http://cds.cern.ch/record/2719661 |
_version_ | 1780965728960118784 |
---|---|
author | Cuesta, C. Belver, D. Boix, J. Calvo, E. Gallego-Ros, A. Gil-Botella, I. Jiménez, S. Lastoria, C. Lux, T. Martin, I. Martinez, J.J. Palomares, C. Redondo, D. Soto-Oton, J. Vargas, D. Verdugo, A. |
author_facet | Cuesta, C. Belver, D. Boix, J. Calvo, E. Gallego-Ros, A. Gil-Botella, I. Jiménez, S. Lastoria, C. Lux, T. Martin, I. Martinez, J.J. Palomares, C. Redondo, D. Soto-Oton, J. Vargas, D. Verdugo, A. |
author_sort | Cuesta, C. |
collection | CERN |
description | A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon
detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3
liquid argon time-projection-chamber (LAr TPC) currently being installed at the Neutrino Platform at CERN. The PDS is based on 36 8-inch photomultiplier tubes (PMTs) and will allow triggering on cosmic rays. The system serves as prototype for the PDS of the final DUNE DP far detector in which the PDS also has the function to allow the 3D event reconstruction on non-beam physics. For this purpose an equalized PMT response is desirable to allow using the same threshold definition for all PMT groups, simplifying the determination of the trigger efficiency. The light calibration system (LCS) described in this paper is developed to provide this and to monitor the PMT performance in-situ. |
format | info:eu-repo/semantics/article |
id | cern-2719661 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
publisher | JINST |
record_format | invenio |
spelling | cern-27196612022-08-10T14:20:52Z doi:10.1088/1748-0221/14/04/T04001 http://cds.cern.ch/record/2719661 eng Cuesta, C. Belver, D. Boix, J. Calvo, E. Gallego-Ros, A. Gil-Botella, I. Jiménez, S. Lastoria, C. Lux, T. Martin, I. Martinez, J.J. Palomares, C. Redondo, D. Soto-Oton, J. Vargas, D. Verdugo, A. A Light Calibration System for the ProtoDUNE-DP Detector Detectors and Experimental Techniques 8: Large scale cryogenic liquid detectors A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber (LAr TPC) currently being installed at the Neutrino Platform at CERN. The PDS is based on 36 8-inch photomultiplier tubes (PMTs) and will allow triggering on cosmic rays. The system serves as prototype for the PDS of the final DUNE DP far detector in which the PDS also has the function to allow the 3D event reconstruction on non-beam physics. For this purpose an equalized PMT response is desirable to allow using the same threshold definition for all PMT groups, simplifying the determination of the trigger efficiency. The light calibration system (LCS) described in this paper is developed to provide this and to monitor the PMT performance in-situ. info:eu-repo/grantAgreement/EC/FP7/654168 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/2719661 JINST JINST, (2019) pp. T04001 2020 |
spellingShingle | Detectors and Experimental Techniques 8: Large scale cryogenic liquid detectors Cuesta, C. Belver, D. Boix, J. Calvo, E. Gallego-Ros, A. Gil-Botella, I. Jiménez, S. Lastoria, C. Lux, T. Martin, I. Martinez, J.J. Palomares, C. Redondo, D. Soto-Oton, J. Vargas, D. Verdugo, A. A Light Calibration System for the ProtoDUNE-DP Detector |
title | A Light Calibration System for the ProtoDUNE-DP Detector |
title_full | A Light Calibration System for the ProtoDUNE-DP Detector |
title_fullStr | A Light Calibration System for the ProtoDUNE-DP Detector |
title_full_unstemmed | A Light Calibration System for the ProtoDUNE-DP Detector |
title_short | A Light Calibration System for the ProtoDUNE-DP Detector |
title_sort | light calibration system for the protodune-dp detector |
topic | Detectors and Experimental Techniques 8: Large scale cryogenic liquid detectors |
url | https://dx.doi.org/10.1088/1748-0221/14/04/T04001 http://cds.cern.ch/record/2719661 http://cds.cern.ch/record/2719661 |
work_keys_str_mv | AT cuestac alightcalibrationsystemfortheprotodunedpdetector AT belverd alightcalibrationsystemfortheprotodunedpdetector AT boixj alightcalibrationsystemfortheprotodunedpdetector AT calvoe alightcalibrationsystemfortheprotodunedpdetector AT gallegorosa alightcalibrationsystemfortheprotodunedpdetector AT gilbotellai alightcalibrationsystemfortheprotodunedpdetector AT jimenezs alightcalibrationsystemfortheprotodunedpdetector AT lastoriac alightcalibrationsystemfortheprotodunedpdetector AT luxt alightcalibrationsystemfortheprotodunedpdetector AT martini alightcalibrationsystemfortheprotodunedpdetector AT martinezjj alightcalibrationsystemfortheprotodunedpdetector AT palomaresc alightcalibrationsystemfortheprotodunedpdetector AT redondod alightcalibrationsystemfortheprotodunedpdetector AT sotootonj alightcalibrationsystemfortheprotodunedpdetector AT vargasd alightcalibrationsystemfortheprotodunedpdetector AT verdugoa alightcalibrationsystemfortheprotodunedpdetector AT cuestac lightcalibrationsystemfortheprotodunedpdetector AT belverd lightcalibrationsystemfortheprotodunedpdetector AT boixj lightcalibrationsystemfortheprotodunedpdetector AT calvoe lightcalibrationsystemfortheprotodunedpdetector AT gallegorosa lightcalibrationsystemfortheprotodunedpdetector AT gilbotellai lightcalibrationsystemfortheprotodunedpdetector AT jimenezs lightcalibrationsystemfortheprotodunedpdetector AT lastoriac lightcalibrationsystemfortheprotodunedpdetector AT luxt lightcalibrationsystemfortheprotodunedpdetector AT martini lightcalibrationsystemfortheprotodunedpdetector AT martinezjj lightcalibrationsystemfortheprotodunedpdetector AT palomaresc lightcalibrationsystemfortheprotodunedpdetector AT redondod lightcalibrationsystemfortheprotodunedpdetector AT sotootonj lightcalibrationsystemfortheprotodunedpdetector AT vargasd lightcalibrationsystemfortheprotodunedpdetector AT verdugoa lightcalibrationsystemfortheprotodunedpdetector |