Cargando…
ATLAS LAr Calorimeter Commissioning for LHC Run-3
Liquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region |η| < 3.2, and for hadronic and forward calorimetry in the region from |η| = 1.5 to |η| = 4.9. In the first LHC run a total luminosity of 27 fb−1 has been collected at...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2725147 |
_version_ | 1780965997783547904 |
---|---|
author | Strizenec, Pavol |
author_facet | Strizenec, Pavol |
author_sort | Strizenec, Pavol |
collection | CERN |
description | Liquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region |η| < 3.2, and for hadronic and forward calorimetry in the region from |η| = 1.5 to |η| = 4.9. In the first LHC run a total luminosity of 27 fb−1 has been collected at center-of-mass energies of 7-8 TeV. After detector consolidation during a long shutdown, Run-2 started in 2015 and about 150fb-1 of data at a center-of-mass energy of 13 TeV was recorded. With the end of Run-2 in 2018 a multi-year shutdown for the Phase-I detector upgrades was begun. As part of the Phase-I upgrade, new trigger readout electronics of the ATLAS Liquid-Argon Calorimeter have been developed. Installation began at the start of the LHC shut down in 2019 and is expected to be completed in 2020. A commissioning campaign is underway in order to realize the capabilities of the new, higher granularity and higher precision level-1 trigger hardware in Run-3 data taking. This contribution will give an overview of the new trigger readout commissioning, as well as the preparations for Run-3 detector operation and changes in the monitoring and data quality procedures to cope with the increased pileup. |
id | cern-2725147 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27251472020-07-30T12:58:59Zhttp://cds.cern.ch/record/2725147engStrizenec, PavolATLAS LAr Calorimeter Commissioning for LHC Run-3Particle Physics - ExperimentLiquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region |η| < 3.2, and for hadronic and forward calorimetry in the region from |η| = 1.5 to |η| = 4.9. In the first LHC run a total luminosity of 27 fb−1 has been collected at center-of-mass energies of 7-8 TeV. After detector consolidation during a long shutdown, Run-2 started in 2015 and about 150fb-1 of data at a center-of-mass energy of 13 TeV was recorded. With the end of Run-2 in 2018 a multi-year shutdown for the Phase-I detector upgrades was begun. As part of the Phase-I upgrade, new trigger readout electronics of the ATLAS Liquid-Argon Calorimeter have been developed. Installation began at the start of the LHC shut down in 2019 and is expected to be completed in 2020. A commissioning campaign is underway in order to realize the capabilities of the new, higher granularity and higher precision level-1 trigger hardware in Run-3 data taking. This contribution will give an overview of the new trigger readout commissioning, as well as the preparations for Run-3 detector operation and changes in the monitoring and data quality procedures to cope with the increased pileup.ATL-LARG-SLIDE-2020-241oai:cds.cern.ch:27251472020-07-27 |
spellingShingle | Particle Physics - Experiment Strizenec, Pavol ATLAS LAr Calorimeter Commissioning for LHC Run-3 |
title | ATLAS LAr Calorimeter Commissioning for LHC Run-3 |
title_full | ATLAS LAr Calorimeter Commissioning for LHC Run-3 |
title_fullStr | ATLAS LAr Calorimeter Commissioning for LHC Run-3 |
title_full_unstemmed | ATLAS LAr Calorimeter Commissioning for LHC Run-3 |
title_short | ATLAS LAr Calorimeter Commissioning for LHC Run-3 |
title_sort | atlas lar calorimeter commissioning for lhc run-3 |
topic | Particle Physics - Experiment |
url | http://cds.cern.ch/record/2725147 |
work_keys_str_mv | AT strizenecpavol atlaslarcalorimetercommissioningforlhcrun3 |