Cargando…
Precision Proton Spectrometer timing detector efficiencies and two-arm timing resolution in 2018 data
The Precision Proton Spectrometer (PPS) is a forward-proton spectrometer using near-beam detectors (inside Roman Pots, RPs) located symmetrically on both sides of IP5 at a distance of about 220 m. In addition to the tracking system, timing detectors were installed in 2017 to measure the Time-Of-Flig...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2740689 |
_version_ | 1780968358100860928 |
---|---|
author | CMS Collaboration |
author_facet | CMS Collaboration |
author_sort | CMS Collaboration |
collection | CERN |
description | The Precision Proton Spectrometer (PPS) is a forward-proton spectrometer
using near-beam detectors
(inside Roman Pots, RPs) located symmetrically on both sides of IP5 at a
distance of about 220 m. In
addition to the tracking system, timing detectors were installed in 2017
to measure the Time-Of-Flight
(TOF) of the protons produced in central exclusive interactions. Two
cylindrical RPs were equipped
with Diamond sensors. In 2018 the TOF system consisted of two single-
and two double-diamond
planes.
This note describes the timing-track efficiency of the sensors in low
and high luminosity runs
and the resolution of the timing system in two-arm events.
Using low pileup data ($\mu$ = interactions/crossing = 1) and selecting
central diffractive events
a strong correlation is observed between the time difference of the
protons detected in PPS,
and the longitudinal vertex position reconstructed in the central CMS
tracker. |
id | cern-2740689 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27406892020-10-21T13:59:55Zhttp://cds.cern.ch/record/2740689engCMS CollaborationPrecision Proton Spectrometer timing detector efficiencies and two-arm timing resolution in 2018 dataDetectors and Experimental TechniquesThe Precision Proton Spectrometer (PPS) is a forward-proton spectrometer using near-beam detectors (inside Roman Pots, RPs) located symmetrically on both sides of IP5 at a distance of about 220 m. In addition to the tracking system, timing detectors were installed in 2017 to measure the Time-Of-Flight (TOF) of the protons produced in central exclusive interactions. Two cylindrical RPs were equipped with Diamond sensors. In 2018 the TOF system consisted of two single- and two double-diamond planes. This note describes the timing-track efficiency of the sensors in low and high luminosity runs and the resolution of the timing system in two-arm events. Using low pileup data ($\mu$ = interactions/crossing = 1) and selecting central diffractive events a strong correlation is observed between the time difference of the protons detected in PPS, and the longitudinal vertex position reconstructed in the central CMS tracker.CMS-DP-2020-046CERN-CMS-DP-2020-046oai:cds.cern.ch:27406892020-09-22 |
spellingShingle | Detectors and Experimental Techniques CMS Collaboration Precision Proton Spectrometer timing detector efficiencies and two-arm timing resolution in 2018 data |
title | Precision Proton Spectrometer timing detector efficiencies and two-arm
timing resolution in 2018 data |
title_full | Precision Proton Spectrometer timing detector efficiencies and two-arm
timing resolution in 2018 data |
title_fullStr | Precision Proton Spectrometer timing detector efficiencies and two-arm
timing resolution in 2018 data |
title_full_unstemmed | Precision Proton Spectrometer timing detector efficiencies and two-arm
timing resolution in 2018 data |
title_short | Precision Proton Spectrometer timing detector efficiencies and two-arm
timing resolution in 2018 data |
title_sort | precision proton spectrometer timing detector efficiencies and two-arm
timing resolution in 2018 data |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/2740689 |
work_keys_str_mv | AT cmscollaboration precisionprotonspectrometertimingdetectorefficienciesandtwoarmtimingresolutionin2018data |