Cargando…
Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
There is an increasing need to shield beams and accelerator elements from stray magnetic fields. The application of magnetic shielding in linear colliders is discussed. The shielding performance of soft iron and mu-metal is measured for magnetic fields of varying amplitude and frequency. Special att...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/15/12/P12030 http://cds.cern.ch/record/2742300 |
_version_ | 1780968502879846400 |
---|---|
author | Gohil, C. Burrows, P.N. Blaskovic Kraljevic, N. Schulte, D. Heilig, B. |
author_facet | Gohil, C. Burrows, P.N. Blaskovic Kraljevic, N. Schulte, D. Heilig, B. |
author_sort | Gohil, C. |
collection | CERN |
description | There is an increasing need to shield beams and accelerator elements from stray magnetic fields. The application of magnetic shielding in linear colliders is discussed. The shielding performance of soft iron and mu-metal is measured for magnetic fields of varying amplitude and frequency. Special attention is given to characterise the shielding performance for very small-amplitude magnetic fields. |
id | cern-2742300 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27423002021-07-28T02:02:32Zdoi:10.1088/1748-0221/15/12/P12030http://cds.cern.ch/record/2742300engGohil, C.Burrows, P.N.Blaskovic Kraljevic, N.Schulte, D.Heilig, B.Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear collidersphysics.acc-phAccelerators and Storage RingsThere is an increasing need to shield beams and accelerator elements from stray magnetic fields. The application of magnetic shielding in linear colliders is discussed. The shielding performance of soft iron and mu-metal is measured for magnetic fields of varying amplitude and frequency. Special attention is given to characterise the shielding performance for very small-amplitude magnetic fields.arXiv:2009.01519oai:cds.cern.ch:27423002020-09-03 |
spellingShingle | physics.acc-ph Accelerators and Storage Rings Gohil, C. Burrows, P.N. Blaskovic Kraljevic, N. Schulte, D. Heilig, B. Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders |
title | Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders |
title_full | Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders |
title_fullStr | Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders |
title_full_unstemmed | Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders |
title_short | Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders |
title_sort | measurements of sub-nt dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders |
topic | physics.acc-ph Accelerators and Storage Rings |
url | https://dx.doi.org/10.1088/1748-0221/15/12/P12030 http://cds.cern.ch/record/2742300 |
work_keys_str_mv | AT gohilc measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders AT burrowspn measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders AT blaskovickraljevicn measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders AT schulted measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders AT heiligb measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders |