Cargando…

Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders

There is an increasing need to shield beams and accelerator elements from stray magnetic fields. The application of magnetic shielding in linear colliders is discussed. The shielding performance of soft iron and mu-metal is measured for magnetic fields of varying amplitude and frequency. Special att...

Descripción completa

Detalles Bibliográficos
Autores principales: Gohil, C., Burrows, P.N., Blaskovic Kraljevic, N., Schulte, D., Heilig, B.
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/15/12/P12030
http://cds.cern.ch/record/2742300
_version_ 1780968502879846400
author Gohil, C.
Burrows, P.N.
Blaskovic Kraljevic, N.
Schulte, D.
Heilig, B.
author_facet Gohil, C.
Burrows, P.N.
Blaskovic Kraljevic, N.
Schulte, D.
Heilig, B.
author_sort Gohil, C.
collection CERN
description There is an increasing need to shield beams and accelerator elements from stray magnetic fields. The application of magnetic shielding in linear colliders is discussed. The shielding performance of soft iron and mu-metal is measured for magnetic fields of varying amplitude and frequency. Special attention is given to characterise the shielding performance for very small-amplitude magnetic fields.
id cern-2742300
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27423002021-07-28T02:02:32Zdoi:10.1088/1748-0221/15/12/P12030http://cds.cern.ch/record/2742300engGohil, C.Burrows, P.N.Blaskovic Kraljevic, N.Schulte, D.Heilig, B.Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear collidersphysics.acc-phAccelerators and Storage RingsThere is an increasing need to shield beams and accelerator elements from stray magnetic fields. The application of magnetic shielding in linear colliders is discussed. The shielding performance of soft iron and mu-metal is measured for magnetic fields of varying amplitude and frequency. Special attention is given to characterise the shielding performance for very small-amplitude magnetic fields.arXiv:2009.01519oai:cds.cern.ch:27423002020-09-03
spellingShingle physics.acc-ph
Accelerators and Storage Rings
Gohil, C.
Burrows, P.N.
Blaskovic Kraljevic, N.
Schulte, D.
Heilig, B.
Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
title Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
title_full Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
title_fullStr Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
title_full_unstemmed Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
title_short Measurements of sub-nT dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
title_sort measurements of sub-nt dynamic magnetic field shielding with soft iron and mu-metal for use in linear colliders
topic physics.acc-ph
Accelerators and Storage Rings
url https://dx.doi.org/10.1088/1748-0221/15/12/P12030
http://cds.cern.ch/record/2742300
work_keys_str_mv AT gohilc measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders
AT burrowspn measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders
AT blaskovickraljevicn measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders
AT schulted measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders
AT heiligb measurementsofsubntdynamicmagneticfieldshieldingwithsoftironandmumetalforuseinlinearcolliders