Cargando…
MD2490 – Measurement of the TMCI threshold at flat-top in the LHC
This report summarizes the results of MD2490 on the measurement of the intensity threshold of the Transverse Mode Coupling Instability (TMCI) in the LHC at flat top. The measurement took place during MD block 3 of 2017, on the night between 15th and 16th September. The betatron tune of bunches with...
Autores principales: | , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2742893 |
_version_ | 1780968527060008960 |
---|---|
author | Albert, Markus Amorim, David Antipov, Sergey Biancacci, Nicolo Buffat, Xavier Carver, Lee Robert Fuchsberger, Kajetan Mereghetti, Alessio Metral, Elias Mounet, Nicolas Salvant, Benoit Valuch, Daniel |
author_facet | Albert, Markus Amorim, David Antipov, Sergey Biancacci, Nicolo Buffat, Xavier Carver, Lee Robert Fuchsberger, Kajetan Mereghetti, Alessio Metral, Elias Mounet, Nicolas Salvant, Benoit Valuch, Daniel |
author_sort | Albert, Markus |
collection | CERN |
description | This report summarizes the results of MD2490 on the measurement of the intensity threshold of the Transverse Mode Coupling Instability (TMCI) in the LHC at flat top. The measurement took place during MD block 3 of 2017, on the night between 15th and 16th September. The betatron tune of bunches with different intensities was measured via ADT excitation and for different collimator settings, thus changing the machine impedance. The tune shift versus intensity measurement allowed to extrapolate the intensity threshold of the TMCI. Relaxing the collimator settings to mimic the HL-LHC impedance reduction also showed the beneficial effect of the collimator upgrade planned for HL-LHC. |
id | cern-2742893 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27428932020-11-19T20:13:08Zhttp://cds.cern.ch/record/2742893engAlbert, MarkusAmorim, DavidAntipov, SergeyBiancacci, NicoloBuffat, XavierCarver, Lee RobertFuchsberger, KajetanMereghetti, AlessioMetral, EliasMounet, NicolasSalvant, BenoitValuch, DanielMD2490 – Measurement of the TMCI threshold at flat-top in the LHCAccelerators and Storage RingsThis report summarizes the results of MD2490 on the measurement of the intensity threshold of the Transverse Mode Coupling Instability (TMCI) in the LHC at flat top. The measurement took place during MD block 3 of 2017, on the night between 15th and 16th September. The betatron tune of bunches with different intensities was measured via ADT excitation and for different collimator settings, thus changing the machine impedance. The tune shift versus intensity measurement allowed to extrapolate the intensity threshold of the TMCI. Relaxing the collimator settings to mimic the HL-LHC impedance reduction also showed the beneficial effect of the collimator upgrade planned for HL-LHC.CERN-ACC-NOTE-2020-0056oai:cds.cern.ch:27428932020-09-28 |
spellingShingle | Accelerators and Storage Rings Albert, Markus Amorim, David Antipov, Sergey Biancacci, Nicolo Buffat, Xavier Carver, Lee Robert Fuchsberger, Kajetan Mereghetti, Alessio Metral, Elias Mounet, Nicolas Salvant, Benoit Valuch, Daniel MD2490 – Measurement of the TMCI threshold at flat-top in the LHC |
title | MD2490 – Measurement of the TMCI threshold at flat-top in the LHC |
title_full | MD2490 – Measurement of the TMCI threshold at flat-top in the LHC |
title_fullStr | MD2490 – Measurement of the TMCI threshold at flat-top in the LHC |
title_full_unstemmed | MD2490 – Measurement of the TMCI threshold at flat-top in the LHC |
title_short | MD2490 – Measurement of the TMCI threshold at flat-top in the LHC |
title_sort | md2490 – measurement of the tmci threshold at flat-top in the lhc |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/2742893 |
work_keys_str_mv | AT albertmarkus md2490measurementofthetmcithresholdatflattopinthelhc AT amorimdavid md2490measurementofthetmcithresholdatflattopinthelhc AT antipovsergey md2490measurementofthetmcithresholdatflattopinthelhc AT biancaccinicolo md2490measurementofthetmcithresholdatflattopinthelhc AT buffatxavier md2490measurementofthetmcithresholdatflattopinthelhc AT carverleerobert md2490measurementofthetmcithresholdatflattopinthelhc AT fuchsbergerkajetan md2490measurementofthetmcithresholdatflattopinthelhc AT mereghettialessio md2490measurementofthetmcithresholdatflattopinthelhc AT metralelias md2490measurementofthetmcithresholdatflattopinthelhc AT mounetnicolas md2490measurementofthetmcithresholdatflattopinthelhc AT salvantbenoit md2490measurementofthetmcithresholdatflattopinthelhc AT valuchdaniel md2490measurementofthetmcithresholdatflattopinthelhc |