The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator

The X-band RF Pulse Compressor (PC) with Correction Cavities was selected as a base line option for the CLIC 380 GeV klystron based accelerator. The recent detailed studies of this system were done few years ago. Since then, the parameters of the accelerating structure have been re-evaluated to impr...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Jinchi, Syratchev, Igor
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:http://cds.cern.ch/record/2742978
_version_ 1780968532897431552
author Cai, Jinchi
Syratchev, Igor
author_facet Cai, Jinchi
Syratchev, Igor
author_sort Cai, Jinchi
collection CERN
description The X-band RF Pulse Compressor (PC) with Correction Cavities was selected as a base line option for the CLIC 380 GeV klystron based accelerator. The recent detailed studies of this system were done few years ago. Since then, the parameters of the accelerating structure have been re-evaluated to improve the accelerator performance. Consequently, the update of the pulse compressor (PC) design is needed to adopt it to the new CLIC accelerating structure requirements. The results of PC optimisation adopted to the new structure parameters are presented in this note.
id cern-2742978
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27429782023-07-20T15:03:24Zhttp://cds.cern.ch/record/2742978engCai, JinchiSyratchev, IgorThe design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based acceleratorAccelerators and Storage RingsThe X-band RF Pulse Compressor (PC) with Correction Cavities was selected as a base line option for the CLIC 380 GeV klystron based accelerator. The recent detailed studies of this system were done few years ago. Since then, the parameters of the accelerating structure have been re-evaluated to improve the accelerator performance. Consequently, the update of the pulse compressor (PC) design is needed to adopt it to the new CLIC accelerating structure requirements. The results of PC optimisation adopted to the new structure parameters are presented in this note.CERN-ACC-2020-0031CLIC-Note-1166oai:cds.cern.ch:27429782020-10-01
spellingShingle Accelerators and Storage Rings
Cai, Jinchi
Syratchev, Igor
The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator
title The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator
title_full The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator
title_fullStr The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator
title_full_unstemmed The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator
title_short The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator
title_sort design update of the x-band rf pulse compressor with correction cavities for the clic 380 gev klystron based accelerator
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2742978
work_keys_str_mv AT caijinchi thedesignupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator
AT syratchevigor thedesignupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator
AT caijinchi designupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator
AT syratchevigor designupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator