Cargando…
The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator
The X-band RF Pulse Compressor (PC) with Correction Cavities was selected as a base line option for the CLIC 380 GeV klystron based accelerator. The recent detailed studies of this system were done few years ago. Since then, the parameters of the accelerating structure have been re-evaluated to impr...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2742978 |
_version_ | 1780968532897431552 |
---|---|
author | Cai, Jinchi Syratchev, Igor |
author_facet | Cai, Jinchi Syratchev, Igor |
author_sort | Cai, Jinchi |
collection | CERN |
description | The X-band RF Pulse Compressor (PC) with Correction Cavities was selected as a base line option for the CLIC 380 GeV klystron based accelerator. The recent detailed studies of this system were done few years ago. Since then, the parameters of the accelerating structure have been re-evaluated to improve the accelerator performance. Consequently, the update of the pulse compressor (PC) design is needed to adopt it to the new CLIC accelerating structure requirements. The results of PC optimisation adopted to the new structure parameters are presented in this note. |
id | cern-2742978 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27429782023-07-20T15:03:24Zhttp://cds.cern.ch/record/2742978engCai, JinchiSyratchev, IgorThe design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based acceleratorAccelerators and Storage RingsThe X-band RF Pulse Compressor (PC) with Correction Cavities was selected as a base line option for the CLIC 380 GeV klystron based accelerator. The recent detailed studies of this system were done few years ago. Since then, the parameters of the accelerating structure have been re-evaluated to improve the accelerator performance. Consequently, the update of the pulse compressor (PC) design is needed to adopt it to the new CLIC accelerating structure requirements. The results of PC optimisation adopted to the new structure parameters are presented in this note.CERN-ACC-2020-0031CLIC-Note-1166oai:cds.cern.ch:27429782020-10-01 |
spellingShingle | Accelerators and Storage Rings Cai, Jinchi Syratchev, Igor The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator |
title | The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator |
title_full | The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator |
title_fullStr | The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator |
title_full_unstemmed | The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator |
title_short | The design update of the X-band RF pulse compressor with Correction Cavities for the CLIC 380 GeV klystron based accelerator |
title_sort | design update of the x-band rf pulse compressor with correction cavities for the clic 380 gev klystron based accelerator |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/2742978 |
work_keys_str_mv | AT caijinchi thedesignupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator AT syratchevigor thedesignupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator AT caijinchi designupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator AT syratchevigor designupdateofthexbandrfpulsecompressorwithcorrectioncavitiesfortheclic380gevklystronbasedaccelerator |