Medipix detectors in radiation therapy for advanced quality-assurance
Spectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are pr...
Autores principales: | , , , , , , , , , , , , |
---|---|
Publicado: |
2020
|
Acceso en línea: | https://dx.doi.org/10.1016/j.radmeas.2019.106211 http://cds.cern.ch/record/2744739 |
_version_ | 1780968642850062336 |
---|---|
author | Rosenfeld, Anatoly Alnaghy, Saree Petasecca, Marco Cutajar, Dean Lerch, Michael Pospisil, Stanislav Giacometti, Valentina Schulte, Reinhard Rosso, Valeria Würl, Matthias Granja, Carlos Martišíková, Mária Parodi, Katia |
author_facet | Rosenfeld, Anatoly Alnaghy, Saree Petasecca, Marco Cutajar, Dean Lerch, Michael Pospisil, Stanislav Giacometti, Valentina Schulte, Reinhard Rosso, Valeria Würl, Matthias Granja, Carlos Martišíková, Mária Parodi, Katia |
author_sort | Rosenfeld, Anatoly |
collection | CERN |
description | Spectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are presented. The technology has been used to develop quality assurance (QA) measurement devices in radiation-based treatments. A gamma camera system for radiotherapy has been developed to measure dose delivered to prostate treatments in real-time. The advantage of a high-resolution detector has been utilized in proton and heavy ion therapy for dose QA, measuring the charge particle spectra, and beam geometry for mini-beams. Applications in medical imaging using helium ion beams have been investigated to replace CT for ion beam radiotherapy. This technique provides many advantages over conventional CT such as high-resolution imaging and spectroscopy-based information for planning in helium ion treatments. The Medipix technology has shown it can be broadly applied in radiation and particle therapy applications for accurate QA as well as proving high-resolution imaging in medicine. |
id | cern-2744739 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2020 |
record_format | invenio |
spelling | cern-27447392022-01-14T14:55:35Zdoi:10.1016/j.radmeas.2019.106211http://cds.cern.ch/record/2744739Rosenfeld, AnatolyAlnaghy, SareePetasecca, MarcoCutajar, DeanLerch, MichaelPospisil, StanislavGiacometti, ValentinaSchulte, ReinhardRosso, ValeriaWürl, MatthiasGranja, CarlosMartišíková, MáriaParodi, KatiaMedipix detectors in radiation therapy for advanced quality-assuranceSpectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are presented. The technology has been used to develop quality assurance (QA) measurement devices in radiation-based treatments. A gamma camera system for radiotherapy has been developed to measure dose delivered to prostate treatments in real-time. The advantage of a high-resolution detector has been utilized in proton and heavy ion therapy for dose QA, measuring the charge particle spectra, and beam geometry for mini-beams. Applications in medical imaging using helium ion beams have been investigated to replace CT for ion beam radiotherapy. This technique provides many advantages over conventional CT such as high-resolution imaging and spectroscopy-based information for planning in helium ion treatments. The Medipix technology has shown it can be broadly applied in radiation and particle therapy applications for accurate QA as well as proving high-resolution imaging in medicine.oai:cds.cern.ch:27447392020 |
spellingShingle | Rosenfeld, Anatoly Alnaghy, Saree Petasecca, Marco Cutajar, Dean Lerch, Michael Pospisil, Stanislav Giacometti, Valentina Schulte, Reinhard Rosso, Valeria Würl, Matthias Granja, Carlos Martišíková, Mária Parodi, Katia Medipix detectors in radiation therapy for advanced quality-assurance |
title | Medipix detectors in radiation therapy for advanced quality-assurance |
title_full | Medipix detectors in radiation therapy for advanced quality-assurance |
title_fullStr | Medipix detectors in radiation therapy for advanced quality-assurance |
title_full_unstemmed | Medipix detectors in radiation therapy for advanced quality-assurance |
title_short | Medipix detectors in radiation therapy for advanced quality-assurance |
title_sort | medipix detectors in radiation therapy for advanced quality-assurance |
url | https://dx.doi.org/10.1016/j.radmeas.2019.106211 http://cds.cern.ch/record/2744739 |
work_keys_str_mv | AT rosenfeldanatoly medipixdetectorsinradiationtherapyforadvancedqualityassurance AT alnaghysaree medipixdetectorsinradiationtherapyforadvancedqualityassurance AT petaseccamarco medipixdetectorsinradiationtherapyforadvancedqualityassurance AT cutajardean medipixdetectorsinradiationtherapyforadvancedqualityassurance AT lerchmichael medipixdetectorsinradiationtherapyforadvancedqualityassurance AT pospisilstanislav medipixdetectorsinradiationtherapyforadvancedqualityassurance AT giacomettivalentina medipixdetectorsinradiationtherapyforadvancedqualityassurance AT schultereinhard medipixdetectorsinradiationtherapyforadvancedqualityassurance AT rossovaleria medipixdetectorsinradiationtherapyforadvancedqualityassurance AT wurlmatthias medipixdetectorsinradiationtherapyforadvancedqualityassurance AT granjacarlos medipixdetectorsinradiationtherapyforadvancedqualityassurance AT martisikovamaria medipixdetectorsinradiationtherapyforadvancedqualityassurance AT parodikatia medipixdetectorsinradiationtherapyforadvancedqualityassurance |