Cargando…

Fixing the nuclear charge density with finite nucleons

<!--HTML-->The measured charge distribution of a nucleus is often used to sample positions of nucleons within the nucleus. However, since nucleons have finite size, the resulting charge distribution is different from the sampled distribution. We show that this can have significant observable...

Descripción completa

Detalles Bibliográficos
Autor principal: Hippert, Mauricio
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:http://cds.cern.ch/record/2749624
_version_ 1780969063458013184
author Hippert, Mauricio
author_facet Hippert, Mauricio
author_sort Hippert, Mauricio
collection CERN
description <!--HTML-->The measured charge distribution of a nucleus is often used to sample positions of nucleons within the nucleus. However, since nucleons have finite size, the resulting charge distribution is different from the sampled distribution. We show that this can have significant observable effects: Not only does it increase the size of the nucleus, but also changes the surface diffusiveness. This in turn can have effects as simple as an overestimate of the transverse size of the collision system resulting in an underestimate of the final transverse momentum, to changes in centrality determination and even total nucleus-nucleus cross section. These differences can, for example, add significant bias to Bayesian parameter estimation. We then show a simple method for correcting this, so that nucleons are sampled in a way that the average charge distribution is fixed to the desired function, and approximately independent of the size of the nucleon. This method can be easily implemented in existing Monte Carlo simulations that utilize a spherical Woods-Saxon distribution. We also discuss a more general treatment that can be used for an arbitrary charge distribution.
id cern-2749624
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27496242022-11-02T22:26:09Zhttp://cds.cern.ch/record/2749624engHippert, MauricioFixing the nuclear charge density with finite nucleonsInitial Stages 2021Conferences<!--HTML-->The measured charge distribution of a nucleus is often used to sample positions of nucleons within the nucleus. However, since nucleons have finite size, the resulting charge distribution is different from the sampled distribution. We show that this can have significant observable effects: Not only does it increase the size of the nucleus, but also changes the surface diffusiveness. This in turn can have effects as simple as an overestimate of the transverse size of the collision system resulting in an underestimate of the final transverse momentum, to changes in centrality determination and even total nucleus-nucleus cross section. These differences can, for example, add significant bias to Bayesian parameter estimation. We then show a simple method for correcting this, so that nucleons are sampled in a way that the average charge distribution is fixed to the desired function, and approximately independent of the size of the nucleon. This method can be easily implemented in existing Monte Carlo simulations that utilize a spherical Woods-Saxon distribution. We also discuss a more general treatment that can be used for an arbitrary charge distribution.oai:cds.cern.ch:27496242021
spellingShingle Conferences
Hippert, Mauricio
Fixing the nuclear charge density with finite nucleons
title Fixing the nuclear charge density with finite nucleons
title_full Fixing the nuclear charge density with finite nucleons
title_fullStr Fixing the nuclear charge density with finite nucleons
title_full_unstemmed Fixing the nuclear charge density with finite nucleons
title_short Fixing the nuclear charge density with finite nucleons
title_sort fixing the nuclear charge density with finite nucleons
topic Conferences
url http://cds.cern.ch/record/2749624
work_keys_str_mv AT hippertmauricio fixingthenuclearchargedensitywithfinitenucleons
AT hippertmauricio initialstages2021