Cargando…
Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement
The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input ca...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2021.165396 http://cds.cern.ch/record/2753771 |
_version_ | 1780969370927759360 |
---|---|
author | Ballabriga, R. Buschmann, E. Campbell, M. Dannheim, D. Dort, K. Egidos, N. Huth, L. Kremastiotis, I. Kroger, J. Linssen, L. Llopart, X. Munker, M. Nürnberg, A. Snoeys, W. Spannagel, S. Vanat, T. Vicente, M. Williams, M. |
author_facet | Ballabriga, R. Buschmann, E. Campbell, M. Dannheim, D. Dort, K. Egidos, N. Huth, L. Kremastiotis, I. Kroger, J. Linssen, L. Llopart, X. Munker, M. Nürnberg, A. Snoeys, W. Spannagel, S. Vanat, T. Vicente, M. Williams, M. |
author_sort | Ballabriga, R. |
collection | CERN |
description | The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the tracking detector studies for the Compact Linear Collider (CLIC). Its design characteristics are of broad interest beyond CLIC, for HL-LHC tracking detector upgrades. It is produced in two different pixel flavours: one with a continuous deep n-type implant, and one with a segmented n-type implant to ensure fast charge collection. The pixel matrix consists of 16 × 128 detection channels measuring 300 μm × 30 μm. Each detection channel is segmented into eight sub-pixels to reduce the amount of digital circuity while maintaining a small collection electrode pitch. This paper presents the characterisation results of the CLICTD sensor in a particle beam. The different pixel flavours are compared in detail by using the simultaneous time-over-threshold and time-of-arrival measurement functionalities. Most notably, a spatial resolution down to (4.6±0.2) μm is measured. A time resolution down to (5.8±0.1) ns is observed, after applying an offline time-walk correction using the pixel-charge information. The hit detection efficiency is found to be well above 99.7 % for thresholds of the order of several hundred electrons. |
id | cern-2753771 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27537712023-01-31T09:07:04Zdoi:10.1016/j.nima.2021.165396http://cds.cern.ch/record/2753771engBallabriga, R.Buschmann, E.Campbell, M.Dannheim, D.Dort, K.Egidos, N.Huth, L.Kremastiotis, I.Kroger, J.Linssen, L.Llopart, X.Munker, M.Nürnberg, A.Snoeys, W.Spannagel, S.Vanat, T.Vicente, M.Williams, M.Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurementhep-exParticle Physics - Experimentphysics.ins-detDetectors and Experimental TechniquesThe CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the tracking detector studies for the Compact Linear Collider (CLIC). Its design characteristics are of broad interest beyond CLIC, for HL-LHC tracking detector upgrades. It is produced in two different pixel flavours: one with a continuous deep n-type implant, and one with a segmented n-type implant to ensure fast charge collection. The pixel matrix consists of 16 × 128 detection channels measuring 300 μm × 30 μm. Each detection channel is segmented into eight sub-pixels to reduce the amount of digital circuity while maintaining a small collection electrode pitch. This paper presents the characterisation results of the CLICTD sensor in a particle beam. The different pixel flavours are compared in detail by using the simultaneous time-over-threshold and time-of-arrival measurement functionalities. Most notably, a spatial resolution down to (4.6±0.2) μm is measured. A time resolution down to (5.8±0.1) ns is observed, after applying an offline time-walk correction using the pixel-charge information. The hit detection efficiency is found to be well above 99.7 % for thresholds of the order of several hundred electrons.The CLIC Tracker Detector (CLICTD) is a monolithic pixel sensor. It is fabricated in a 180 nm CMOS imaging process, modified with an additional deep low-dose n-type implant to obtain full lateral depletion. The sensor features a small collection diode, which is essential for achieving a low input capacitance. The CLICTD sensor was designed as a technology demonstrator in the context of the tracking detector studies for the Compact Linear Collider (CLIC). Its design characteristics are of broad interest beyond CLIC, for HL-LHC tracking detector upgrades. It is produced in two different pixel flavours: one with a continuous deep n-type implant, and one with a segmented n-type implant to ensure fast charge collection. The pixel matrix consists of $16\times128$ detection channels measuring $300 \times 30$ microns. Each detection channel is segmented into eight sub-pixels to reduce the amount of digital circuity while maintaining a small collection electrode pitch. This paper presents the characterisation results of the CLICTD sendor in a particle beam. The different pixel flavours are compared in detail by using the simultaneous time-over-threshold and time-of-arrival measurement functionalities. Most notably, a time resolution down to $(5.8 \pm 0.1)$ ns and a spatial resolution down to $(4.6 \pm 0.2)$ microns are measured. The hit detection efficiency is found to be well above 99.7% for thresholds of the order of several hundred electrons.arXiv:2102.04025oai:cds.cern.ch:27537712021-02-08 |
spellingShingle | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques Ballabriga, R. Buschmann, E. Campbell, M. Dannheim, D. Dort, K. Egidos, N. Huth, L. Kremastiotis, I. Kroger, J. Linssen, L. Llopart, X. Munker, M. Nürnberg, A. Snoeys, W. Spannagel, S. Vanat, T. Vicente, M. Williams, M. Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement |
title | Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement |
title_full | Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement |
title_fullStr | Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement |
title_full_unstemmed | Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement |
title_short | Test-beam characterisation of the CLICTD technology demonstrator - a small collection electrode High-Resistivity CMOS pixel sensor with simultaneous time and energy measurement |
title_sort | test-beam characterisation of the clictd technology demonstrator - a small collection electrode high-resistivity cmos pixel sensor with simultaneous time and energy measurement |
topic | hep-ex Particle Physics - Experiment physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2021.165396 http://cds.cern.ch/record/2753771 |
work_keys_str_mv | AT ballabrigar testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT buschmanne testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT campbellm testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT dannheimd testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT dortk testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT egidosn testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT huthl testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT kremastiotisi testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT krogerj testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT linssenl testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT llopartx testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT munkerm testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT nurnberga testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT snoeysw testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT spannagels testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT vanatt testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT vicentem testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement AT williamsm testbeamcharacterisationoftheclictdtechnologydemonstratorasmallcollectionelectrodehighresistivitycmospixelsensorwithsimultaneoustimeandenergymeasurement |