Cargando…
The level-1 calorimeter trigger for the CMS detector at LHC
The level-1 calorimeter trigger system for the CMS detector at LHC collider provides a deadtimeless pipelined trigger that implements simple algorithms which satisfy the physics efficiency and data rate requirements. We plan to run the trigger system at 160 MHz in order to provide a compact system b...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1994
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/275953 |
_version_ | 1780887515856633856 |
---|---|
author | Dasu, S Górski, T Lackey, J R Panescu, D Smith, W H Temple, W |
author_facet | Dasu, S Górski, T Lackey, J R Panescu, D Smith, W H Temple, W |
author_sort | Dasu, S |
collection | CERN |
description | The level-1 calorimeter trigger system for the CMS detector at LHC collider provides a deadtimeless pipelined trigger that implements simple algorithms which satisfy the physics efficiency and data rate requirements. We plan to run the trigger system at 160 MHz in order to provide a compact system by quadrupling the use of most components and data paths within an LHC crossing of 40 MHz. Many logic elements in the design are implemented in custom integrated circuits with much attention paid to the trigger data optimization and the latency in processing. Through extensive simulation of the level-1 calorimeter trigger, we have determined the background rates and efficiencies for various triggers such as those for electrons, photons, jets and neutrinos. |
id | cern-275953 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1994 |
record_format | invenio |
spelling | cern-2759532019-09-30T06:29:59Zhttp://cds.cern.ch/record/275953engDasu, SGórski, TLackey, J RPanescu, DSmith, W HTemple, WThe level-1 calorimeter trigger for the CMS detector at LHCDetectors and Experimental TechniquesThe level-1 calorimeter trigger system for the CMS detector at LHC collider provides a deadtimeless pipelined trigger that implements simple algorithms which satisfy the physics efficiency and data rate requirements. We plan to run the trigger system at 160 MHz in order to provide a compact system by quadrupling the use of most components and data paths within an LHC crossing of 40 MHz. Many logic elements in the design are implemented in custom integrated circuits with much attention paid to the trigger data optimization and the latency in processing. Through extensive simulation of the level-1 calorimeter trigger, we have determined the background rates and efficiencies for various triggers such as those for electrons, photons, jets and neutrinos.CMS-TN-94-264WISC-EX-94-342oai:cds.cern.ch:2759531994 |
spellingShingle | Detectors and Experimental Techniques Dasu, S Górski, T Lackey, J R Panescu, D Smith, W H Temple, W The level-1 calorimeter trigger for the CMS detector at LHC |
title | The level-1 calorimeter trigger for the CMS detector at LHC |
title_full | The level-1 calorimeter trigger for the CMS detector at LHC |
title_fullStr | The level-1 calorimeter trigger for the CMS detector at LHC |
title_full_unstemmed | The level-1 calorimeter trigger for the CMS detector at LHC |
title_short | The level-1 calorimeter trigger for the CMS detector at LHC |
title_sort | level-1 calorimeter trigger for the cms detector at lhc |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/275953 |
work_keys_str_mv | AT dasus thelevel1calorimetertriggerforthecmsdetectoratlhc AT gorskit thelevel1calorimetertriggerforthecmsdetectoratlhc AT lackeyjr thelevel1calorimetertriggerforthecmsdetectoratlhc AT panescud thelevel1calorimetertriggerforthecmsdetectoratlhc AT smithwh thelevel1calorimetertriggerforthecmsdetectoratlhc AT templew thelevel1calorimetertriggerforthecmsdetectoratlhc AT dasus level1calorimetertriggerforthecmsdetectoratlhc AT gorskit level1calorimetertriggerforthecmsdetectoratlhc AT lackeyjr level1calorimetertriggerforthecmsdetectoratlhc AT panescud level1calorimetertriggerforthecmsdetectoratlhc AT smithwh level1calorimetertriggerforthecmsdetectoratlhc AT templew level1calorimetertriggerforthecmsdetectoratlhc |