Cargando…

CMS Silicon Strip Tracker Performance during Run 2

The performance of the CMS Silicon Strip Tracker is monitored on a run by run basis using the CMS Offline Data Quality Monitoring Software. Among the quantities that are monitored, there are the overall fraction of bad components, the fractions of bad components broken down by readout partition and...

Descripción completa

Detalles Bibliográficos
Autor principal: CMS Collaboration
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:http://cds.cern.ch/record/2759969
_version_ 1780970246979452928
author CMS Collaboration
author_facet CMS Collaboration
author_sort CMS Collaboration
collection CERN
description The performance of the CMS Silicon Strip Tracker is monitored on a run by run basis using the CMS Offline Data Quality Monitoring Software. Among the quantities that are monitored, there are the overall fraction of bad components, the fractions of bad components broken down by readout partition and the cluster charge normalized to the traversed silicon length. In this note we present the evolution of these quantities as a function of the integrated delivered luminosity by the LHC during the years 2016, 2017 and 2018. The total fraction of bad components is found to be fluctuating around 4\% and it is remarkably stable during the considered period. Thanks to the dedicated offline calibration, the most probable value of a Landau fit to Strip cluster charge is equalized within a 10\% excursion during the considered period.
id cern-2759969
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27599692021-04-06T19:03:07Zhttp://cds.cern.ch/record/2759969engCMS CollaborationCMS Silicon Strip Tracker Performance during Run 2Detectors and Experimental TechniquesThe performance of the CMS Silicon Strip Tracker is monitored on a run by run basis using the CMS Offline Data Quality Monitoring Software. Among the quantities that are monitored, there are the overall fraction of bad components, the fractions of bad components broken down by readout partition and the cluster charge normalized to the traversed silicon length. In this note we present the evolution of these quantities as a function of the integrated delivered luminosity by the LHC during the years 2016, 2017 and 2018. The total fraction of bad components is found to be fluctuating around 4\% and it is remarkably stable during the considered period. Thanks to the dedicated offline calibration, the most probable value of a Landau fit to Strip cluster charge is equalized within a 10\% excursion during the considered period.CMS-DP-2021-003CERN-CMS-DP-2021-003oai:cds.cern.ch:27599692021-03-14
spellingShingle Detectors and Experimental Techniques
CMS Collaboration
CMS Silicon Strip Tracker Performance during Run 2
title CMS Silicon Strip Tracker Performance during Run 2
title_full CMS Silicon Strip Tracker Performance during Run 2
title_fullStr CMS Silicon Strip Tracker Performance during Run 2
title_full_unstemmed CMS Silicon Strip Tracker Performance during Run 2
title_short CMS Silicon Strip Tracker Performance during Run 2
title_sort cms silicon strip tracker performance during run 2
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2759969
work_keys_str_mv AT cmscollaboration cmssiliconstriptrackerperformanceduringrun2