Cargando…

Gating of charge sensitive preamplifiers for the use at pulsed radiation sources

The development of a switch circuit to gate charge sensitive preamplifiers for use at pulsed radiation sources will be presented. This development was used for the $^{16}$O(n,$\alpha$)$^{13}$C reaction measurement with a Double Frisch Grid Ionization Chamber (DFGIC) at the neutron time-of-flight fa...

Descripción completa

Detalles Bibliográficos
Autores principales: Urlass, Sebastian, Junghans, Arnd, Mingrone, Federica, Peronnard, Paul, Stach, Daniel, Tassan-Got, Laurent, Weinberger, David
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2021.165297
http://cds.cern.ch/record/2764444
_version_ 1780971114842816512
author Urlass, Sebastian
Junghans, Arnd
Mingrone, Federica
Peronnard, Paul
Stach, Daniel
Tassan-Got, Laurent
Weinberger, David
author_facet Urlass, Sebastian
Junghans, Arnd
Mingrone, Federica
Peronnard, Paul
Stach, Daniel
Tassan-Got, Laurent
Weinberger, David
author_sort Urlass, Sebastian
collection CERN
description The development of a switch circuit to gate charge sensitive preamplifiers for use at pulsed radiation sources will be presented. This development was used for the $^{16}$O(n,$\alpha$)$^{13}$C reaction measurement with a Double Frisch Grid Ionization Chamber (DFGIC) at the neutron time-of-flight facility CERN n_TOF in Geneva, Switzerland. Intense instantaneous radiation which is produced in the spallation target of the n_TOF facility ($\gamma$-flash) can saturate charge sensitive preamplifiers and prevent signals from being registered in the detection system. The switch circuit made it possible for the first time to perform a measurement with the DFGIC with -flash gated off at n_TOF. Nano-second gating of charge sensitive preamplifiers has a wide range of applicability at pulsed radiation sources, where short bursts of radiation must be gated off to avoid saturation, e.g. with HPGe detectors for -ray detection. Nano-second gating requires the stray-capacitance of the wideband reflective switch to be compensated to avoid a strong signal during the switch operation. Spectral analysis of the switch circuit shows that additional noise is insignificant.
id cern-2764444
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27644442021-05-31T14:07:27Zdoi:10.1016/j.nima.2021.165297http://cds.cern.ch/record/2764444engUrlass, SebastianJunghans, ArndMingrone, FedericaPeronnard, PaulStach, DanielTassan-Got, LaurentWeinberger, DavidGating of charge sensitive preamplifiers for the use at pulsed radiation sourcesDetectors and Experimental TechniquesThe development of a switch circuit to gate charge sensitive preamplifiers for use at pulsed radiation sources will be presented. This development was used for the $^{16}$O(n,$\alpha$)$^{13}$C reaction measurement with a Double Frisch Grid Ionization Chamber (DFGIC) at the neutron time-of-flight facility CERN n_TOF in Geneva, Switzerland. Intense instantaneous radiation which is produced in the spallation target of the n_TOF facility ($\gamma$-flash) can saturate charge sensitive preamplifiers and prevent signals from being registered in the detection system. The switch circuit made it possible for the first time to perform a measurement with the DFGIC with -flash gated off at n_TOF. Nano-second gating of charge sensitive preamplifiers has a wide range of applicability at pulsed radiation sources, where short bursts of radiation must be gated off to avoid saturation, e.g. with HPGe detectors for -ray detection. Nano-second gating requires the stray-capacitance of the wideband reflective switch to be compensated to avoid a strong signal during the switch operation. Spectral analysis of the switch circuit shows that additional noise is insignificant.oai:cds.cern.ch:27644442021-03-31
spellingShingle Detectors and Experimental Techniques
Urlass, Sebastian
Junghans, Arnd
Mingrone, Federica
Peronnard, Paul
Stach, Daniel
Tassan-Got, Laurent
Weinberger, David
Gating of charge sensitive preamplifiers for the use at pulsed radiation sources
title Gating of charge sensitive preamplifiers for the use at pulsed radiation sources
title_full Gating of charge sensitive preamplifiers for the use at pulsed radiation sources
title_fullStr Gating of charge sensitive preamplifiers for the use at pulsed radiation sources
title_full_unstemmed Gating of charge sensitive preamplifiers for the use at pulsed radiation sources
title_short Gating of charge sensitive preamplifiers for the use at pulsed radiation sources
title_sort gating of charge sensitive preamplifiers for the use at pulsed radiation sources
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2021.165297
http://cds.cern.ch/record/2764444
work_keys_str_mv AT urlasssebastian gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources
AT junghansarnd gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources
AT mingronefederica gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources
AT peronnardpaul gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources
AT stachdaniel gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources
AT tassangotlaurent gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources
AT weinbergerdavid gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources