Cargando…
Gating of charge sensitive preamplifiers for the use at pulsed radiation sources
The development of a switch circuit to gate charge sensitive preamplifiers for use at pulsed radiation sources will be presented. This development was used for the $^{16}$O(n,$\alpha$)$^{13}$C reaction measurement with a Double Frisch Grid Ionization Chamber (DFGIC) at the neutron time-of-flight fa...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2021.165297 http://cds.cern.ch/record/2764444 |
_version_ | 1780971114842816512 |
---|---|
author | Urlass, Sebastian Junghans, Arnd Mingrone, Federica Peronnard, Paul Stach, Daniel Tassan-Got, Laurent Weinberger, David |
author_facet | Urlass, Sebastian Junghans, Arnd Mingrone, Federica Peronnard, Paul Stach, Daniel Tassan-Got, Laurent Weinberger, David |
author_sort | Urlass, Sebastian |
collection | CERN |
description | The development of a switch circuit to gate charge sensitive preamplifiers for use at pulsed radiation sources will be presented. This development was used for the $^{16}$O(n,$\alpha$)$^{13}$C reaction measurement with a Double Frisch Grid Ionization Chamber (DFGIC) at the neutron time-of-flight facility CERN n_TOF in Geneva, Switzerland. Intense instantaneous radiation which is produced in the spallation target of the n_TOF facility ($\gamma$-flash) can saturate charge sensitive preamplifiers and prevent signals from being registered in the detection system. The switch circuit made it possible for the first time to perform a measurement with the DFGIC with -flash gated off at n_TOF. Nano-second gating of charge sensitive preamplifiers has a wide range of applicability at pulsed radiation sources, where short bursts of radiation must be gated off to avoid saturation, e.g. with HPGe detectors for -ray detection. Nano-second gating requires the stray-capacitance of the wideband reflective switch to be compensated to avoid a strong signal during the switch operation. Spectral analysis of the switch circuit shows that additional noise is insignificant. |
id | cern-2764444 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27644442021-05-31T14:07:27Zdoi:10.1016/j.nima.2021.165297http://cds.cern.ch/record/2764444engUrlass, SebastianJunghans, ArndMingrone, FedericaPeronnard, PaulStach, DanielTassan-Got, LaurentWeinberger, DavidGating of charge sensitive preamplifiers for the use at pulsed radiation sourcesDetectors and Experimental TechniquesThe development of a switch circuit to gate charge sensitive preamplifiers for use at pulsed radiation sources will be presented. This development was used for the $^{16}$O(n,$\alpha$)$^{13}$C reaction measurement with a Double Frisch Grid Ionization Chamber (DFGIC) at the neutron time-of-flight facility CERN n_TOF in Geneva, Switzerland. Intense instantaneous radiation which is produced in the spallation target of the n_TOF facility ($\gamma$-flash) can saturate charge sensitive preamplifiers and prevent signals from being registered in the detection system. The switch circuit made it possible for the first time to perform a measurement with the DFGIC with -flash gated off at n_TOF. Nano-second gating of charge sensitive preamplifiers has a wide range of applicability at pulsed radiation sources, where short bursts of radiation must be gated off to avoid saturation, e.g. with HPGe detectors for -ray detection. Nano-second gating requires the stray-capacitance of the wideband reflective switch to be compensated to avoid a strong signal during the switch operation. Spectral analysis of the switch circuit shows that additional noise is insignificant.oai:cds.cern.ch:27644442021-03-31 |
spellingShingle | Detectors and Experimental Techniques Urlass, Sebastian Junghans, Arnd Mingrone, Federica Peronnard, Paul Stach, Daniel Tassan-Got, Laurent Weinberger, David Gating of charge sensitive preamplifiers for the use at pulsed radiation sources |
title | Gating of charge sensitive preamplifiers for the use at pulsed radiation sources |
title_full | Gating of charge sensitive preamplifiers for the use at pulsed radiation sources |
title_fullStr | Gating of charge sensitive preamplifiers for the use at pulsed radiation sources |
title_full_unstemmed | Gating of charge sensitive preamplifiers for the use at pulsed radiation sources |
title_short | Gating of charge sensitive preamplifiers for the use at pulsed radiation sources |
title_sort | gating of charge sensitive preamplifiers for the use at pulsed radiation sources |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2021.165297 http://cds.cern.ch/record/2764444 |
work_keys_str_mv | AT urlasssebastian gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources AT junghansarnd gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources AT mingronefederica gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources AT peronnardpaul gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources AT stachdaniel gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources AT tassangotlaurent gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources AT weinbergerdavid gatingofchargesensitivepreamplifiersfortheuseatpulsedradiationsources |