High-accuracy liquid-sample β-NMR setup at ISOLDE
Recently there has been an increased interest to apply the sensitive <math display="inline" id="d1e639" altimg="si42.svg"><mi>β</mi></math>-decay asymmetry detected nuclear magnetic resonance (<math display="inline" id="d1e645&q...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2021.165862 http://cds.cern.ch/record/2765258 |
_version_ | 1780971140914610176 |
---|---|
author | Croese, J. Baranowski, M. Bissell, M.L. Dziubinska-Kühn, K.M. Gins, W. Harding, R.D. Jolivet, R.B. Kanellakopoulos, A. Karg, B. Kulesz, K. Flores, M. Madurga Neyens, G. Pallada, S. Pietrzykc, R. Pomorski, M. Wagenknecht, P. Zakouckyk, D. Kowalska, M. |
author_facet | Croese, J. Baranowski, M. Bissell, M.L. Dziubinska-Kühn, K.M. Gins, W. Harding, R.D. Jolivet, R.B. Kanellakopoulos, A. Karg, B. Kulesz, K. Flores, M. Madurga Neyens, G. Pallada, S. Pietrzykc, R. Pomorski, M. Wagenknecht, P. Zakouckyk, D. Kowalska, M. |
author_sort | Croese, J. |
collection | CERN |
description | Recently there has been an increased interest to apply the sensitive <math display="inline" id="d1e639" altimg="si42.svg"><mi>β</mi></math>-decay asymmetry detected nuclear magnetic resonance (<math display="inline" id="d1e645" altimg="si42.svg"><mi>β</mi></math>-NMR) technique to biological studies. A liquid-sample <math display="inline" id="d1e650" altimg="si42.svg"><mi>β</mi></math>-NMR setup was build at ISOLDE to allow such investigations and to use the resolution gain of liquid-state NMR in nuclear physics. As part of this setup a magnetic field locking system, a set of printed circuit board shimming coils, a sample exchange system, a set of compact <math display="inline" id="d1e656" altimg="si42.svg"><mi>β</mi></math>-detectors and a custom experimental vacuum chamber were developed. The main magnetic field was stabilized down to the ppm level by the locking system while allowing the direct determination of the absolute magnetic field. The homogeneity of the magnetic field was improved to <math display="inline" id="d1e661" altimg="si5.svg"><mo>≤</mo></math> 5 ppm over the sample volume by the shimming coils. Time spent on changing samples was reduced by a factor of five by the liquid sample exchange system. During experiments it was possible to continuously observe the liquid sample thanks to the custom chamber and compact <math display="inline" id="d1e666" altimg="si42.svg"><mi>β</mi></math>-detectors. The absolute field determination allows for a novel way to reference <math display="inline" id="d1e671" altimg="si42.svg"><mi>β</mi></math>-NMR measurements, removing the need for time consuming reference measurements. The improved accuracy and resolution resulting from these innovations allows the study of the distribution of nuclear magnetization and (bio)chemicals using high-accuracy liquid-sample <math display="inline" id="d1e677" altimg="si42.svg"><mi>β</mi></math>-NMR. |
id | cern-2765258 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27652582021-12-03T07:04:09Zdoi:10.1016/j.nima.2021.165862http://cds.cern.ch/record/2765258engCroese, J.Baranowski, M.Bissell, M.L.Dziubinska-Kühn, K.M.Gins, W.Harding, R.D.Jolivet, R.B.Kanellakopoulos, A.Karg, B.Kulesz, K.Flores, M. MadurgaNeyens, G.Pallada, S.Pietrzykc, R.Pomorski, M.Wagenknecht, P.Zakouckyk, D.Kowalska, M.High-accuracy liquid-sample β-NMR setup at ISOLDEphysics.ins-detDetectors and Experimental TechniquesRecently there has been an increased interest to apply the sensitive <math display="inline" id="d1e639" altimg="si42.svg"><mi>β</mi></math>-decay asymmetry detected nuclear magnetic resonance (<math display="inline" id="d1e645" altimg="si42.svg"><mi>β</mi></math>-NMR) technique to biological studies. A liquid-sample <math display="inline" id="d1e650" altimg="si42.svg"><mi>β</mi></math>-NMR setup was build at ISOLDE to allow such investigations and to use the resolution gain of liquid-state NMR in nuclear physics. As part of this setup a magnetic field locking system, a set of printed circuit board shimming coils, a sample exchange system, a set of compact <math display="inline" id="d1e656" altimg="si42.svg"><mi>β</mi></math>-detectors and a custom experimental vacuum chamber were developed. The main magnetic field was stabilized down to the ppm level by the locking system while allowing the direct determination of the absolute magnetic field. The homogeneity of the magnetic field was improved to <math display="inline" id="d1e661" altimg="si5.svg"><mo>≤</mo></math> 5 ppm over the sample volume by the shimming coils. Time spent on changing samples was reduced by a factor of five by the liquid sample exchange system. During experiments it was possible to continuously observe the liquid sample thanks to the custom chamber and compact <math display="inline" id="d1e666" altimg="si42.svg"><mi>β</mi></math>-detectors. The absolute field determination allows for a novel way to reference <math display="inline" id="d1e671" altimg="si42.svg"><mi>β</mi></math>-NMR measurements, removing the need for time consuming reference measurements. The improved accuracy and resolution resulting from these innovations allows the study of the distribution of nuclear magnetization and (bio)chemicals using high-accuracy liquid-sample <math display="inline" id="d1e677" altimg="si42.svg"><mi>β</mi></math>-NMR.Recently there has been an increased interest to apply the sensitive $\beta$-decay asymmetry detected nuclear magnetic resonance ($\beta$-NMR) technique to biological studies. A liquid-sample $\beta$-NMR setup was build at ISOLDE to allow such investigations and to use the resolution gain of liquid-state NMR in nuclear physics. As part of this setup a magnetic field locking system, a set of printed circuit board shimming coils, a sample exchange system, a set of compact $\beta$-detectors and a custom experimental vacuum chamber were developed. The main magnetic field was stabilized down to the ppm level by the locking system while allowing the direct determination of the absolute magnetic field. The homogeneity of the magnetic field was improved to $\leq$~5~ppm over the sample volume by the shimming coils. Time spent on changing samples was reduced by a factor of five by the liquid sample exchange system. During experiments it was possible to continuously observe the liquid sample thanks to the custom chamber and compact $\beta$-detectors. The absolute field determination allows for a novel way to reference $\beta$-NMR measurements, removing the need for time consuming reference measurements. The improved accuracy and resolution resulting from these innovations allows the study of the distribution of nuclear magnetization and (bio)chemicals using high-accuracy liquid-sample $\beta$-NMR.arXiv:2104.11326oai:cds.cern.ch:27652582021-04-20 |
spellingShingle | physics.ins-det Detectors and Experimental Techniques Croese, J. Baranowski, M. Bissell, M.L. Dziubinska-Kühn, K.M. Gins, W. Harding, R.D. Jolivet, R.B. Kanellakopoulos, A. Karg, B. Kulesz, K. Flores, M. Madurga Neyens, G. Pallada, S. Pietrzykc, R. Pomorski, M. Wagenknecht, P. Zakouckyk, D. Kowalska, M. High-accuracy liquid-sample β-NMR setup at ISOLDE |
title | High-accuracy liquid-sample β-NMR setup at ISOLDE |
title_full | High-accuracy liquid-sample β-NMR setup at ISOLDE |
title_fullStr | High-accuracy liquid-sample β-NMR setup at ISOLDE |
title_full_unstemmed | High-accuracy liquid-sample β-NMR setup at ISOLDE |
title_short | High-accuracy liquid-sample β-NMR setup at ISOLDE |
title_sort | high-accuracy liquid-sample β-nmr setup at isolde |
topic | physics.ins-det Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2021.165862 http://cds.cern.ch/record/2765258 |
work_keys_str_mv | AT croesej highaccuracyliquidsamplebnmrsetupatisolde AT baranowskim highaccuracyliquidsamplebnmrsetupatisolde AT bissellml highaccuracyliquidsamplebnmrsetupatisolde AT dziubinskakuhnkm highaccuracyliquidsamplebnmrsetupatisolde AT ginsw highaccuracyliquidsamplebnmrsetupatisolde AT hardingrd highaccuracyliquidsamplebnmrsetupatisolde AT jolivetrb highaccuracyliquidsamplebnmrsetupatisolde AT kanellakopoulosa highaccuracyliquidsamplebnmrsetupatisolde AT kargb highaccuracyliquidsamplebnmrsetupatisolde AT kuleszk highaccuracyliquidsamplebnmrsetupatisolde AT floresmmadurga highaccuracyliquidsamplebnmrsetupatisolde AT neyensg highaccuracyliquidsamplebnmrsetupatisolde AT palladas highaccuracyliquidsamplebnmrsetupatisolde AT pietrzykcr highaccuracyliquidsamplebnmrsetupatisolde AT pomorskim highaccuracyliquidsamplebnmrsetupatisolde AT wagenknechtp highaccuracyliquidsamplebnmrsetupatisolde AT zakouckykd highaccuracyliquidsamplebnmrsetupatisolde AT kowalskam highaccuracyliquidsamplebnmrsetupatisolde |