Cargando…
A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test results
The increase of the particle flux (pile-up) at the HL-LHC with luminosities of L ≃ 7.5 × 1034 cm$^{−2}$s$^{−1}$ will have a severe impact on the ATLAS detector reconstruction and trigger performance. The end-cap and forward region where the liquid Argon calorimeter has coarser granularity and the in...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2774663 |
_version_ | 1780971554291580928 |
---|---|
author | Imam, Hajar |
author_facet | Imam, Hajar |
author_sort | Imam, Hajar |
collection | CERN |
description | The increase of the particle flux (pile-up) at the HL-LHC with luminosities of L ≃ 7.5 × 1034 cm$^{−2}$s$^{−1}$ will have a severe impact on the ATLAS detector reconstruction and trigger performance. The end-cap and forward region where the liquid Argon calorimeter has coarser granularity and the inner tracker has poorer longitudinal vertex position resolution will be particularly affected. A High Granularity Timing Detector (HGTD) is proposed in front of the LAr end-cap calorimeters for pile-up mitigation and for luminosity measurement. It will cover the pseudo-rapidity range from 2.4 to 4.0. Two Silicon sensors double sided layers will provide precision timing information for MIPs with a resolution better than 30 ps per track in order to assign each particle to the correct vertex. Readout cells have a size of 1.3 mm × 1.3 mm, leading to a highly granular detector with 3 millions of channels. Low Gain Avalanche Detectors (LGAD) technology has been chosen as it provides enough gain to reach the large signal over noise ratio needed. A dedicated ASIC is being developed and some prototypes have been already submitted and measured The requirements and overall specifications of the HGTD will be discussed. LGAD R&D campaigns are carried out to study the sensors, the related ASICs, and the radiation hardness. Laboratory and test beam results will be presented. |
id | cern-2774663 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27746632021-07-02T20:04:26Zhttp://cds.cern.ch/record/2774663engImam, HajarA High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test resultsParticle Physics - ExperimentThe increase of the particle flux (pile-up) at the HL-LHC with luminosities of L ≃ 7.5 × 1034 cm$^{−2}$s$^{−1}$ will have a severe impact on the ATLAS detector reconstruction and trigger performance. The end-cap and forward region where the liquid Argon calorimeter has coarser granularity and the inner tracker has poorer longitudinal vertex position resolution will be particularly affected. A High Granularity Timing Detector (HGTD) is proposed in front of the LAr end-cap calorimeters for pile-up mitigation and for luminosity measurement. It will cover the pseudo-rapidity range from 2.4 to 4.0. Two Silicon sensors double sided layers will provide precision timing information for MIPs with a resolution better than 30 ps per track in order to assign each particle to the correct vertex. Readout cells have a size of 1.3 mm × 1.3 mm, leading to a highly granular detector with 3 millions of channels. Low Gain Avalanche Detectors (LGAD) technology has been chosen as it provides enough gain to reach the large signal over noise ratio needed. A dedicated ASIC is being developed and some prototypes have been already submitted and measured The requirements and overall specifications of the HGTD will be discussed. LGAD R&D campaigns are carried out to study the sensors, the related ASICs, and the radiation hardness. Laboratory and test beam results will be presented.ATL-HGTD-SLIDE-2021-308oai:cds.cern.ch:27746632021-07-02 |
spellingShingle | Particle Physics - Experiment Imam, Hajar A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test results |
title | A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test results |
title_full | A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test results |
title_fullStr | A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test results |
title_full_unstemmed | A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test results |
title_short | A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system: detector concept, description and R&D and beam test results |
title_sort | high-granularity timing detector for the phase-ii upgrade of the atlas calorimeter system: detector concept, description and r&d and beam test results |
topic | Particle Physics - Experiment |
url | http://cds.cern.ch/record/2774663 |
work_keys_str_mv | AT imamhajar ahighgranularitytimingdetectorforthephaseiiupgradeoftheatlascalorimetersystemdetectorconceptdescriptionandrdandbeamtestresults AT imamhajar highgranularitytimingdetectorforthephaseiiupgradeoftheatlascalorimetersystemdetectorconceptdescriptionandrdandbeamtestresults |