Cargando…
Comparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeT
The KM3NeT Collaboration has successfully deployed the first detection units of the next generation undersea neutrino telescopes in the Mediterranean Sea at the two sites in Italy and in France. The data sample collected between December 2016 and January 2020 has been used to measure the atmospheric...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.22323/1.395.1112 http://cds.cern.ch/record/2776524 |
_version_ | 1780971620968431616 |
---|---|
author | Kalaczyński, Piotr |
author_facet | Kalaczyński, Piotr |
author_sort | Kalaczyński, Piotr |
collection | CERN |
description | The KM3NeT Collaboration has successfully deployed the first detection units of the next generation undersea neutrino telescopes in the Mediterranean Sea at the two sites in Italy and in France. The data sample collected between December 2016 and January 2020 has been used to measure the atmospheric muon rate at two different depths under the sea level: 3.5 km with KM3NeT-ARCA and 2.5 km with KM3NeT-ORCA. Atmospheric muons represent an abundant signal in a neutrino telescope and can be used to test the reliability of the Monte Carlo simulation chain and to study the physics of extensive air showers caused by highly-energetic primary nuclei impinging the Earth's atmosphere. At energies above PeV the contribution from prompt muons, created right after the first interaction in the shower, is expected to become dominant, however its existence has not yet been experimentally confirmed. In this talk, data collected with the first detection units of KM3NeT are compared to Monte Carlo simulations based on MUPAGE and CORSIKA codes. The main features of the simulation and reconstruction chains are presented. Additionally, the first results of the simulated signal from the prompt muon component for KM3NeT-ARCA and KM3NeT-ORCA obtained with CORSIKA are discussed. |
id | cern-2776524 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27765242021-12-17T09:00:52Zdoi:10.22323/1.395.1112http://cds.cern.ch/record/2776524engKalaczyński, PiotrComparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeTphysics.ins-detDetectors and Experimental Techniqueshep-exParticle Physics - ExperimentThe KM3NeT Collaboration has successfully deployed the first detection units of the next generation undersea neutrino telescopes in the Mediterranean Sea at the two sites in Italy and in France. The data sample collected between December 2016 and January 2020 has been used to measure the atmospheric muon rate at two different depths under the sea level: 3.5 km with KM3NeT-ARCA and 2.5 km with KM3NeT-ORCA. Atmospheric muons represent an abundant signal in a neutrino telescope and can be used to test the reliability of the Monte Carlo simulation chain and to study the physics of extensive air showers caused by highly-energetic primary nuclei impinging the Earth's atmosphere. At energies above PeV the contribution from prompt muons, created right after the first interaction in the shower, is expected to become dominant, however its existence has not yet been experimentally confirmed. In this talk, data collected with the first detection units of KM3NeT are compared to Monte Carlo simulations based on MUPAGE and CORSIKA codes. The main features of the simulation and reconstruction chains are presented. Additionally, the first results of the simulated signal from the prompt muon component for KM3NeT-ARCA and KM3NeT-ORCA obtained with CORSIKA are discussed.arXiv:2107.09347oai:cds.cern.ch:27765242021 |
spellingShingle | physics.ins-det Detectors and Experimental Techniques hep-ex Particle Physics - Experiment Kalaczyński, Piotr Comparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeT |
title | Comparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeT |
title_full | Comparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeT |
title_fullStr | Comparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeT |
title_full_unstemmed | Comparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeT |
title_short | Comparison of the measured atmospheric muon rate with Monte Carlo simulations and sensitivity study for detection of prompt atmospheric muons with KM3NeT |
title_sort | comparison of the measured atmospheric muon rate with monte carlo simulations and sensitivity study for detection of prompt atmospheric muons with km3net |
topic | physics.ins-det Detectors and Experimental Techniques hep-ex Particle Physics - Experiment |
url | https://dx.doi.org/10.22323/1.395.1112 http://cds.cern.ch/record/2776524 |
work_keys_str_mv | AT kalaczynskipiotr comparisonofthemeasuredatmosphericmuonratewithmontecarlosimulationsandsensitivitystudyfordetectionofpromptatmosphericmuonswithkm3net |