Cargando…

Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs

To cope up with high pile-up rates during Phase-2 operation of the LHC, the CMS experiment will install a precision Minimum Ionising Particle Timing Detector (MTD), between the tracker and calorimeter, which will have a timing resolution of $\sim$30~ps. The endcap part of the MTD, called the Endcap...

Descripción completa

Detalles Bibliográficos
Autor principal: Bharthuar, Shudhashil
Lenguaje:eng
Publicado: 2020
Materias:
Acceso en línea:http://cds.cern.ch/record/2779267
_version_ 1780971788055871488
author Bharthuar, Shudhashil
author_facet Bharthuar, Shudhashil
author_sort Bharthuar, Shudhashil
collection CERN
description To cope up with high pile-up rates during Phase-2 operation of the LHC, the CMS experiment will install a precision Minimum Ionising Particle Timing Detector (MTD), between the tracker and calorimeter, which will have a timing resolution of $\sim$30~ps. The endcap part of the MTD, called the Endcap Timing Layer (ETL), will be based on Low-Gain Avalanche Detector (LGAD) Technology.\\ In this paper, the authors have performed a study on UFSD3.1 LGAD production from Fondazione Bruno Kessler (FBK). The objective of this production was to optimise the interplay between the p-stop dose and the inter-pad terminal strategy. Results show that the nominal no-gain region width value between pads does not affect the breakdown voltage of the sensors at low p-stop doses. A comparative study on the effect of thermal donors induced in the bulk of the sensor was performed by capacitance versus voltage measurements. Further, the property of the sensors were investigated using infra-red (IR) laser, by performing voltage scans and inter-pad profile measurements with gain variation, on changing temperature in Transient Current Technique (TCT). Results show no significant change in the charge collection efficiency and measured no-gain region width values of sensors irrespective of the nature of the bulk.
id cern-2779267
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2020
record_format invenio
spelling cern-27792672021-08-26T20:59:52Zhttp://cds.cern.ch/record/2779267engBharthuar, ShudhashilEffect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADsDetectors and Experimental TechniquesTo cope up with high pile-up rates during Phase-2 operation of the LHC, the CMS experiment will install a precision Minimum Ionising Particle Timing Detector (MTD), between the tracker and calorimeter, which will have a timing resolution of $\sim$30~ps. The endcap part of the MTD, called the Endcap Timing Layer (ETL), will be based on Low-Gain Avalanche Detector (LGAD) Technology.\\ In this paper, the authors have performed a study on UFSD3.1 LGAD production from Fondazione Bruno Kessler (FBK). The objective of this production was to optimise the interplay between the p-stop dose and the inter-pad terminal strategy. Results show that the nominal no-gain region width value between pads does not affect the breakdown voltage of the sensors at low p-stop doses. A comparative study on the effect of thermal donors induced in the bulk of the sensor was performed by capacitance versus voltage measurements. Further, the property of the sensors were investigated using infra-red (IR) laser, by performing voltage scans and inter-pad profile measurements with gain variation, on changing temperature in Transient Current Technique (TCT). Results show no significant change in the charge collection efficiency and measured no-gain region width values of sensors irrespective of the nature of the bulk.CMS-CR-2020-230oai:cds.cern.ch:27792672020-11-08
spellingShingle Detectors and Experimental Techniques
Bharthuar, Shudhashil
Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs
title Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs
title_full Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs
title_fullStr Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs
title_full_unstemmed Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs
title_short Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs
title_sort effect of thermal donors induced in bulk and variation in p-stop dose on the no-gain region width measurements of lgads
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2779267
work_keys_str_mv AT bharthuarshudhashil effectofthermaldonorsinducedinbulkandvariationinpstopdoseonthenogainregionwidthmeasurementsoflgads