Cargando…
Commissioning the Phase-1 LAr Upgrade
Liquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region ${|\eta| < 3.2}$, and for hadronic and forward calorimetry in the region from ${|\eta| = 1.5}$ to ${|\eta| = 4.9}$. In the first LHC run (Run-1), a total luminosity of...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2779554 |
_version_ | 1780971815133249536 |
---|---|
author | Kay, Ellis |
author_facet | Kay, Ellis |
author_sort | Kay, Ellis |
collection | CERN |
description | Liquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region ${|\eta| < 3.2}$, and for hadronic and forward calorimetry in the region from ${|\eta| = 1.5}$ to ${|\eta| = 4.9}$. In the first LHC run (Run-1), a total luminosity of 27~fb\textsuperscript{-1} was collected at centre-of-mass energies of 7-8~TeV. After detector consolidation during a long shutdown, Run-2 started in 2015 and around 150~fb\textsuperscript{-1} of data at a centre-of-mass energy of 13~TeV was recorded. With the end of Run-2 in 2018, a multi-year shutdown for the Phase-I detector upgrades began. As part of the Phase-I upgrade, new trigger readout electronics of the ATLAS Liquid-Argon Calorimeter have been developed. Installation began at the start of the LHC shut down in 2019 and is expected to be completed in 2020. A commissioning campaign is underway in order to realise the capabilities of the new, higher granularity and higher precision level-1 trigger hardware in Run-3 data taking. This contribution will give an overview of the new trigger readout system and the ongoing commissioning and installation efforts. |
id | cern-2779554 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27795542021-08-30T21:50:25Zhttp://cds.cern.ch/record/2779554engKay, EllisCommissioning the Phase-1 LAr UpgradeParticle Physics - ExperimentLiquid argon (LAr) sampling calorimeters are employed by ATLAS for all electromagnetic calorimetry in the pseudo-rapidity region ${|\eta| < 3.2}$, and for hadronic and forward calorimetry in the region from ${|\eta| = 1.5}$ to ${|\eta| = 4.9}$. In the first LHC run (Run-1), a total luminosity of 27~fb\textsuperscript{-1} was collected at centre-of-mass energies of 7-8~TeV. After detector consolidation during a long shutdown, Run-2 started in 2015 and around 150~fb\textsuperscript{-1} of data at a centre-of-mass energy of 13~TeV was recorded. With the end of Run-2 in 2018, a multi-year shutdown for the Phase-I detector upgrades began. As part of the Phase-I upgrade, new trigger readout electronics of the ATLAS Liquid-Argon Calorimeter have been developed. Installation began at the start of the LHC shut down in 2019 and is expected to be completed in 2020. A commissioning campaign is underway in order to realise the capabilities of the new, higher granularity and higher precision level-1 trigger hardware in Run-3 data taking. This contribution will give an overview of the new trigger readout system and the ongoing commissioning and installation efforts.ATL-LARG-PROC-2021-004oai:cds.cern.ch:27795542021-08-30 |
spellingShingle | Particle Physics - Experiment Kay, Ellis Commissioning the Phase-1 LAr Upgrade |
title | Commissioning the Phase-1 LAr Upgrade |
title_full | Commissioning the Phase-1 LAr Upgrade |
title_fullStr | Commissioning the Phase-1 LAr Upgrade |
title_full_unstemmed | Commissioning the Phase-1 LAr Upgrade |
title_short | Commissioning the Phase-1 LAr Upgrade |
title_sort | commissioning the phase-1 lar upgrade |
topic | Particle Physics - Experiment |
url | http://cds.cern.ch/record/2779554 |
work_keys_str_mv | AT kayellis commissioningthephase1larupgrade |