Cargando…
Aging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHC
Concurrently with the high-luminosity LHC (HL-LHC) upgrade, the Compact Muon Solenoid (CMS) experiment is renovating some of its subsystems. In particular, in the muon spectrometer region, Triple-GEM detectors will be installed to cope with the high-rate environment and to maintain the actual perfor...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/15/05/C05002 http://cds.cern.ch/record/2780271 |
_version_ | 1780971856798416896 |
---|---|
author | Fiorina, Davide |
author_facet | Fiorina, Davide |
author_sort | Fiorina, Davide |
collection | CERN |
description | Concurrently with the high-luminosity LHC (HL-LHC) upgrade, the Compact Muon Solenoid (CMS) experiment is renovating some of its subsystems.
In particular, in the muon spectrometer region, Triple-GEM detectors will be installed to cope with the high-rate environment and to maintain the actual performance of the detector.
In this work we summarize the aging tests performed to validate the Triple-GEM technology for the CMS purpose. Furthermore the tests and results completed to amplify the knowledge of the aging issue in Triple-GEMs and gaseous detectors in general are presented, with some hint for future test to perform. |
id | cern-2780271 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | cern-27802712022-01-18T10:17:53Zdoi:10.1088/1748-0221/15/05/C05002http://cds.cern.ch/record/2780271engFiorina, DavideAging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHCDetectors and Experimental TechniquesConcurrently with the high-luminosity LHC (HL-LHC) upgrade, the Compact Muon Solenoid (CMS) experiment is renovating some of its subsystems. In particular, in the muon spectrometer region, Triple-GEM detectors will be installed to cope with the high-rate environment and to maintain the actual performance of the detector. In this work we summarize the aging tests performed to validate the Triple-GEM technology for the CMS purpose. Furthermore the tests and results completed to amplify the knowledge of the aging issue in Triple-GEMs and gaseous detectors in general are presented, with some hint for future test to perform.Concurrently with the high-luminosity LHC (HL-LHC) upgrade, the Compact Muon Solenoid (CMS) experiment is renovating some of its subsystems. In particular, in the muon spectrometer region, Triple-GEM detectors will be installed to cope with the high-rate environment and to maintain the actual performance of the detector. In this work we summarize the aging tests performed to validate the Triple-GEM technology for the CMS purpose. Furthermore the tests and results completed to amplify the knowledge of the aging issue in Triple-GEMs and gaseous detectors in general are presented, with some hint for future test to perform.CMS-CR-2019-311oai:cds.cern.ch:27802712019-12-26 |
spellingShingle | Detectors and Experimental Techniques Fiorina, Davide Aging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHC |
title | Aging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHC |
title_full | Aging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHC |
title_fullStr | Aging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHC |
title_full_unstemmed | Aging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHC |
title_short | Aging studies of Triple-GEM detectors for future upgrades of the CMS endcap muon system at the HL-LHC |
title_sort | aging studies of triple-gem detectors for future upgrades of the cms endcap muon system at the hl-lhc |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/15/05/C05002 http://cds.cern.ch/record/2780271 |
work_keys_str_mv | AT fiorinadavide agingstudiesoftriplegemdetectorsforfutureupgradesofthecmsendcapmuonsystematthehllhc |