Cargando…

An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC

The cooling systems of the future tracking detectors of the ATLAS and CMS experiments at the Large Hadron Collider (LHC) at CERN will be entirely based on CO$_2$ refrigeration technology. The system is a booster refrigeration system, composed of a two stage primary part with transcritical R744 equip...

Descripción completa

Detalles Bibliográficos
Autores principales: Barroca, Pierre, Hafner, Armin, Verlaat, Bart, Petagna, Paolo, Hulek, Wojciech, Zwalinski, Lukasz, Hanf, Pierre, Battistin, Michele, Davoine, Loic, Teixeira, Daniella
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:https://dx.doi.org/10.3390/app11167399
http://cds.cern.ch/record/2780496
_version_ 1780971879855554560
author Barroca, Pierre
Hafner, Armin
Verlaat, Bart
Petagna, Paolo
Hulek, Wojciech
Zwalinski, Lukasz
Hanf, Pierre
Battistin, Michele
Davoine, Loic
Teixeira, Daniella
author_facet Barroca, Pierre
Hafner, Armin
Verlaat, Bart
Petagna, Paolo
Hulek, Wojciech
Zwalinski, Lukasz
Hanf, Pierre
Battistin, Michele
Davoine, Loic
Teixeira, Daniella
author_sort Barroca, Pierre
collection CERN
description The cooling systems of the future tracking detectors of the ATLAS and CMS experiments at the Large Hadron Collider (LHC) at CERN will be entirely based on CO$_2$ refrigeration technology. The system is a booster refrigeration system, composed of a two stage primary part with transcritical R744 equipment and a low temperature secondary CO2 pumped loop. The primary refrigeration sub-system installed on surface provides cold R744 at −53$^∘$C to the CO$_2$ pumped loops installed 100 m underground and rejects the heat exchanged. The process must be reliable and remain stable regardless of the amount of heat exchanged, which will amount to hundreds of kilowatts and is expected to vary throughout the lifetime of the detectors. The paper discusses the concept adopted for the innovative transcritical R744 cycle and describes the technical details of the first prototype built.
id cern-2780496
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27804962021-09-17T07:29:48Zdoi:10.3390/app11167399http://cds.cern.ch/record/2780496engBarroca, PierreHafner, ArminVerlaat, BartPetagna, PaoloHulek, WojciechZwalinski, LukaszHanf, PierreBattistin, MicheleDavoine, LoicTeixeira, DaniellaAn Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHCDetectors and Experimental TechniquesThe cooling systems of the future tracking detectors of the ATLAS and CMS experiments at the Large Hadron Collider (LHC) at CERN will be entirely based on CO$_2$ refrigeration technology. The system is a booster refrigeration system, composed of a two stage primary part with transcritical R744 equipment and a low temperature secondary CO2 pumped loop. The primary refrigeration sub-system installed on surface provides cold R744 at −53$^∘$C to the CO$_2$ pumped loops installed 100 m underground and rejects the heat exchanged. The process must be reliable and remain stable regardless of the amount of heat exchanged, which will amount to hundreds of kilowatts and is expected to vary throughout the lifetime of the detectors. The paper discusses the concept adopted for the innovative transcritical R744 cycle and describes the technical details of the first prototype built.oai:cds.cern.ch:27804962021
spellingShingle Detectors and Experimental Techniques
Barroca, Pierre
Hafner, Armin
Verlaat, Bart
Petagna, Paolo
Hulek, Wojciech
Zwalinski, Lukasz
Hanf, Pierre
Battistin, Michele
Davoine, Loic
Teixeira, Daniella
An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
title An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
title_full An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
title_fullStr An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
title_full_unstemmed An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
title_short An Ultra-Low Temperature Transcritical R744 Refrigeration System for Future Detectors at CERN LHC
title_sort ultra-low temperature transcritical r744 refrigeration system for future detectors at cern lhc
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.3390/app11167399
http://cds.cern.ch/record/2780496
work_keys_str_mv AT barrocapierre anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT hafnerarmin anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT verlaatbart anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT petagnapaolo anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT hulekwojciech anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT zwalinskilukasz anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT hanfpierre anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT battistinmichele anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT davoineloic anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT teixeiradaniella anultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT barrocapierre ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT hafnerarmin ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT verlaatbart ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT petagnapaolo ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT hulekwojciech ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT zwalinskilukasz ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT hanfpierre ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT battistinmichele ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT davoineloic ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc
AT teixeiradaniella ultralowtemperaturetranscriticalr744refrigerationsystemforfuturedetectorsatcernlhc