Cargando…

Development of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCb

This project focuses on developing trigger lines for the KS0 → 2(e+e−) decay considering the detectors and geometry of the LHCb. This type of decays constitute a strong test for the Standard Model, and could point to dark sector light-mass candidates. The implemented trigger line was run on MC signa...

Descripción completa

Detalles Bibliográficos
Autor principal: Quevedo Diaz, Sebastian
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:http://cds.cern.ch/record/2780812
_version_ 1780971897858555904
author Quevedo Diaz, Sebastian
author_facet Quevedo Diaz, Sebastian
author_sort Quevedo Diaz, Sebastian
collection CERN
description This project focuses on developing trigger lines for the KS0 → 2(e+e−) decay considering the detectors and geometry of the LHCb. This type of decays constitute a strong test for the Standard Model, and could point to dark sector light-mass candidates. The implemented trigger line was run on MC signal and a HLT1-filtered Minimum Bias simulation samples in order to study the lines efficiency, which was of the order of 10−1 for the MC samples and 10−3 for Minimum Bias. Clear separation of the signal and the background was not achieved but clear ideas for further improvements were proposed.
id cern-2780812
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27808122021-09-13T20:51:19Zhttp://cds.cern.ch/record/2780812engQuevedo Diaz, SebastianDevelopment of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCbPhysics in GeneralThis project focuses on developing trigger lines for the KS0 → 2(e+e−) decay considering the detectors and geometry of the LHCb. This type of decays constitute a strong test for the Standard Model, and could point to dark sector light-mass candidates. The implemented trigger line was run on MC signal and a HLT1-filtered Minimum Bias simulation samples in order to study the lines efficiency, which was of the order of 10−1 for the MC samples and 10−3 for Minimum Bias. Clear separation of the signal and the background was not achieved but clear ideas for further improvements were proposed.CERN-STUDENTS-Note-2021-152oai:cds.cern.ch:27808122021-09-13
spellingShingle Physics in General
Quevedo Diaz, Sebastian
Development of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCb
title Development of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCb
title_full Development of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCb
title_fullStr Development of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCb
title_full_unstemmed Development of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCb
title_short Development of Run 3 HLT2 lines for KS0 → 2(e+e−) decays at LHCb
title_sort development of run 3 hlt2 lines for ks0 → 2(e+e−) decays at lhcb
topic Physics in General
url http://cds.cern.ch/record/2780812
work_keys_str_mv AT quevedodiazsebastian developmentofrun3hlt2linesforks02eedecaysatlhcb