Upgrade of the ATLAS Tilecal High Voltage system

The high voltage (HV) system of TileCal, the ATLAS central hadron calorimeter, is being upgraded for the HL-LHC, in the so called Phase II Upgrade. In the new configuration for the upgrade, the HV regulation boards are not located inside the detector anymore, they are deployed far from the radiation...

Descripción completa

Detalles Bibliográficos
Autores principales: Da Silva Gomes, Agostinho, Soares Augusto, Jose Antonio, Mendes De Oliveira Cuim, Filipe, Gaspar De Andrade Evans, Guiomar, Serrano Fernandez, Rui Paulo, Da Silva Gurriana, Luis Miguel, Martins, Filipe, Ponte Pereira, Catarina Jose, Fernandes Marques, Rui Miguel
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:http://cds.cern.ch/record/2781229
Descripción
Sumario:The high voltage (HV) system of TileCal, the ATLAS central hadron calorimeter, is being upgraded for the HL-LHC, in the so called Phase II Upgrade. In the new configuration for the upgrade, the HV regulation boards are not located inside the detector anymore, they are deployed far from the radiation in a room where there is permanent access for maintenance. This option requires a large number of 100 m long HV cables but removes the requirement of radiation hard boards. HVremote regulation boards and the respective HV supplies boards have been developed and tested, as well as a crate to house the boards. Preliminary results of the performance will be presented.