Cargando…
HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter
<!--HTML-->For the CMS HGCAL, the final version of the 72-channel front-end ASIC (HGCROC3) was submitted in December 2020. HGCROC3 includes low-noise/high-gain preamplifier/shapers, and a 10-bit 40 MHz SAR-ADC, which provides the charge measurement over the linear range of the preamplifier. In...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2781956 |
_version_ | 1780971970584641536 |
---|---|
author | Dulucq, Frederic |
author_facet | Dulucq, Frederic |
author_sort | Dulucq, Frederic |
collection | CERN |
description | <!--HTML-->For the CMS HGCAL, the final version of the 72-channel front-end ASIC (HGCROC3) was submitted in December 2020. HGCROC3 includes low-noise/high-gain preamplifier/shapers, and a 10-bit 40 MHz SAR-ADC, which provides the charge measurement over the linear range of the preamplifier. In the saturation range a discriminator and TDC provide the charge information from TOT (200ns dynamic range, 50ps binning). A fast discriminator and TDC provide timing information to 25ps accuracy. The chip embeds all necessary ancillary services: bandgap circuit, PLL, threshold DACs. We present the experimental results on the latest and final version HGCROC3 received in April 2021. |
id | cern-2781956 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27819562022-11-02T22:02:15Zhttp://cds.cern.ch/record/2781956engDulucq, FredericHGCROC3: the front-end readout ASIC for the CMS High Granularity CalorimeterTWEPP 2021 Topical Workshop on Electronics for Particle PhysicsConferences<!--HTML-->For the CMS HGCAL, the final version of the 72-channel front-end ASIC (HGCROC3) was submitted in December 2020. HGCROC3 includes low-noise/high-gain preamplifier/shapers, and a 10-bit 40 MHz SAR-ADC, which provides the charge measurement over the linear range of the preamplifier. In the saturation range a discriminator and TDC provide the charge information from TOT (200ns dynamic range, 50ps binning). A fast discriminator and TDC provide timing information to 25ps accuracy. The chip embeds all necessary ancillary services: bandgap circuit, PLL, threshold DACs. We present the experimental results on the latest and final version HGCROC3 received in April 2021.oai:cds.cern.ch:27819562021 |
spellingShingle | Conferences Dulucq, Frederic HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_full | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_fullStr | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_full_unstemmed | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_short | HGCROC3: the front-end readout ASIC for the CMS High Granularity Calorimeter |
title_sort | hgcroc3: the front-end readout asic for the cms high granularity calorimeter |
topic | Conferences |
url | http://cds.cern.ch/record/2781956 |
work_keys_str_mv | AT dulucqfrederic hgcroc3thefrontendreadoutasicforthecmshighgranularitycalorimeter AT dulucqfrederic twepp2021topicalworkshoponelectronicsforparticlephysics |