Cargando…

A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET

Time of flight positron emission tomography can strongly benefit from a very accurate time estimator given by Cherenkov radiation, which is produced upon a 511 keV positron–electron annihilation gamma interaction in heavy inorganic scintillators. While time resolution in the order of 30 ps full widt...

Descripción completa

Detalles Bibliográficos
Autores principales: Kratochwil, Nicolaus, Gundacker, Stefan, Auffray, Etiennette
Lenguaje:eng
Publicado: 2021
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1361-6560/ac212a
http://cds.cern.ch/record/2782141
_version_ 1780971982975664128
author Kratochwil, Nicolaus
Gundacker, Stefan
Auffray, Etiennette
author_facet Kratochwil, Nicolaus
Gundacker, Stefan
Auffray, Etiennette
author_sort Kratochwil, Nicolaus
collection CERN
description Time of flight positron emission tomography can strongly benefit from a very accurate time estimator given by Cherenkov radiation, which is produced upon a 511 keV positron–electron annihilation gamma interaction in heavy inorganic scintillators. While time resolution in the order of 30 ps full width at half maximum (FWHM) has been reported using MCP-PMTs and black painted Cherenkov radiators, such solutions have several disadvantages, like high cost and low detection efficiency of nowadays available MCP-PMTs. On the other hand, silicon photomultipliers (SiPMs) are not limited by those obstacles and provide high photon detection efficiency with a decent time response. Timing performance of PbF2 crystals of various lengths and surface conditions coupled to SiPMs was evaluated against a reference detector with an optimized test setup using high-frequency readout and novel time walk correction, with special attention on the intrinsic limits for one detected Cherenkov photon only. The average number of detected Cherenkov photons largely depends on the crystal surface state, resulting in a tradeoff between low photon time spread, thus good timing performance, and sensitivity. An intrinsic Cherenkov photon yield of 16.5 ± 3.3 was calculated for 2 × 2 × 3 mm$^3$ sized PbF$_2$ crystals upon 511 keV $\gamma$-deposition. After time walk correction based on the slew rate of the signal, assuming two identical detector arms in coincidence, and using all events, a time resolution of 215 ps FWHM (142 ps FWHM) was obtained for 2 × 2 × 20 mm$^3$ (2 × 2 × 3 mm$^3$) sized PbF$_2$ crystals, compared to 261 ps (190 ps) without correction. Selecting on one detected photon only, a single photon coincidence time resolution of 113 ps FWHM for black painted and 166 ps for Teflon wrapped crystals was measured for 3 mm length, compared to 145 ps (black) and 263 ps (Teflon) for 20 mm length.
id cern-2782141
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2021
record_format invenio
spelling cern-27821412021-09-29T14:27:30Zdoi:10.1088/1361-6560/ac212ahttp://cds.cern.ch/record/2782141engKratochwil, NicolausGundacker, StefanAuffray, EtiennetteA roadmap for sole Cherenkov radiators with SiPMs in TOF-PETDetectors and Experimental TechniquesTime of flight positron emission tomography can strongly benefit from a very accurate time estimator given by Cherenkov radiation, which is produced upon a 511 keV positron–electron annihilation gamma interaction in heavy inorganic scintillators. While time resolution in the order of 30 ps full width at half maximum (FWHM) has been reported using MCP-PMTs and black painted Cherenkov radiators, such solutions have several disadvantages, like high cost and low detection efficiency of nowadays available MCP-PMTs. On the other hand, silicon photomultipliers (SiPMs) are not limited by those obstacles and provide high photon detection efficiency with a decent time response. Timing performance of PbF2 crystals of various lengths and surface conditions coupled to SiPMs was evaluated against a reference detector with an optimized test setup using high-frequency readout and novel time walk correction, with special attention on the intrinsic limits for one detected Cherenkov photon only. The average number of detected Cherenkov photons largely depends on the crystal surface state, resulting in a tradeoff between low photon time spread, thus good timing performance, and sensitivity. An intrinsic Cherenkov photon yield of 16.5 ± 3.3 was calculated for 2 × 2 × 3 mm$^3$ sized PbF$_2$ crystals upon 511 keV $\gamma$-deposition. After time walk correction based on the slew rate of the signal, assuming two identical detector arms in coincidence, and using all events, a time resolution of 215 ps FWHM (142 ps FWHM) was obtained for 2 × 2 × 20 mm$^3$ (2 × 2 × 3 mm$^3$) sized PbF$_2$ crystals, compared to 261 ps (190 ps) without correction. Selecting on one detected photon only, a single photon coincidence time resolution of 113 ps FWHM for black painted and 166 ps for Teflon wrapped crystals was measured for 3 mm length, compared to 145 ps (black) and 263 ps (Teflon) for 20 mm length.oai:cds.cern.ch:27821412021
spellingShingle Detectors and Experimental Techniques
Kratochwil, Nicolaus
Gundacker, Stefan
Auffray, Etiennette
A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET
title A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET
title_full A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET
title_fullStr A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET
title_full_unstemmed A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET
title_short A roadmap for sole Cherenkov radiators with SiPMs in TOF-PET
title_sort roadmap for sole cherenkov radiators with sipms in tof-pet
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1361-6560/ac212a
http://cds.cern.ch/record/2782141
work_keys_str_mv AT kratochwilnicolaus aroadmapforsolecherenkovradiatorswithsipmsintofpet
AT gundackerstefan aroadmapforsolecherenkovradiatorswithsipmsintofpet
AT auffrayetiennette aroadmapforsolecherenkovradiatorswithsipmsintofpet
AT kratochwilnicolaus roadmapforsolecherenkovradiatorswithsipmsintofpet
AT gundackerstefan roadmapforsolecherenkovradiatorswithsipmsintofpet
AT auffrayetiennette roadmapforsolecherenkovradiatorswithsipmsintofpet