Cargando…
The Gotthard-II readout ASIC and detector system
<!--HTML-->Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV–20 keV. Its potential scientific applications include X-ray absorption/emission spectroscopy, energy dispersive experiments, as well a...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2782324 |
_version_ | 1780971993512804352 |
---|---|
author | Zhang, Jiaguo |
author_facet | Zhang, Jiaguo |
author_sort | Zhang, Jiaguo |
collection | CERN |
description | <!--HTML-->Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV–20 keV. Its potential scientific applications include X-ray absorption/emission spectroscopy, energy dispersive experiments, as well as veto signal generation for pixel detectors. The Gotthard-II ASIC has been designed in several optimization steps in order to meet the requirements of the European XFEL, i.e. single photon sensitivity, large dynamic range as well as a high frame rate of 4.5 MHz. The ASIC design and performance will be presented. The detector system as well as the results from beam tests will be discussed. |
id | cern-2782324 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27823242022-11-02T22:02:14Zhttp://cds.cern.ch/record/2782324engZhang, JiaguoThe Gotthard-II readout ASIC and detector systemTWEPP 2021 Topical Workshop on Electronics for Particle PhysicsConferences<!--HTML-->Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV–20 keV. Its potential scientific applications include X-ray absorption/emission spectroscopy, energy dispersive experiments, as well as veto signal generation for pixel detectors. The Gotthard-II ASIC has been designed in several optimization steps in order to meet the requirements of the European XFEL, i.e. single photon sensitivity, large dynamic range as well as a high frame rate of 4.5 MHz. The ASIC design and performance will be presented. The detector system as well as the results from beam tests will be discussed.oai:cds.cern.ch:27823242021 |
spellingShingle | Conferences Zhang, Jiaguo The Gotthard-II readout ASIC and detector system |
title | The Gotthard-II readout ASIC and detector system |
title_full | The Gotthard-II readout ASIC and detector system |
title_fullStr | The Gotthard-II readout ASIC and detector system |
title_full_unstemmed | The Gotthard-II readout ASIC and detector system |
title_short | The Gotthard-II readout ASIC and detector system |
title_sort | gotthard-ii readout asic and detector system |
topic | Conferences |
url | http://cds.cern.ch/record/2782324 |
work_keys_str_mv | AT zhangjiaguo thegotthardiireadoutasicanddetectorsystem AT zhangjiaguo twepp2021topicalworkshoponelectronicsforparticlephysics AT zhangjiaguo gotthardiireadoutasicanddetectorsystem |