Integration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3
<!--HTML-->The Muon-to-Central Trigger Processor Interface (MUCTPI) was completely redesigned as part of the ATLAS Level-1 trigger upgrade for Run 3 of the LHC. The new system is implemented as a single ATCA module, using three large state-of-the-art FPGAs and high-density fibre-optic modules....
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2021
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2782406 |
_version_ | 1780972000966082560 |
---|---|
author | Perrella, Sabrina |
author_facet | Perrella, Sabrina |
author_sort | Perrella, Sabrina |
collection | CERN |
description | <!--HTML-->The Muon-to-Central Trigger Processor Interface (MUCTPI) was completely redesigned as part of the ATLAS Level-1 trigger upgrade for Run 3 of the LHC. The new system is implemented as a single ATCA module, using three large state-of-the-art FPGAs and high-density fibre-optic modules. 208 high‑speed links receive trigger information from the muon trigger detectors, while 60 links are used to send processed trigger information to the Topological Trigger and the Central-Trigger-Processor. Extensive integration tests with all input and output systems have shown that the data transfer is stable and reliable. We will also report on the commissioning of the MUCTPI. |
id | cern-2782406 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2021 |
record_format | invenio |
spelling | cern-27824062022-11-02T22:02:13Zhttp://cds.cern.ch/record/2782406engPerrella, SabrinaIntegration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3TWEPP 2021 Topical Workshop on Electronics for Particle PhysicsConferences<!--HTML-->The Muon-to-Central Trigger Processor Interface (MUCTPI) was completely redesigned as part of the ATLAS Level-1 trigger upgrade for Run 3 of the LHC. The new system is implemented as a single ATCA module, using three large state-of-the-art FPGAs and high-density fibre-optic modules. 208 high‑speed links receive trigger information from the muon trigger detectors, while 60 links are used to send processed trigger information to the Topological Trigger and the Central-Trigger-Processor. Extensive integration tests with all input and output systems have shown that the data transfer is stable and reliable. We will also report on the commissioning of the MUCTPI.oai:cds.cern.ch:27824062021 |
spellingShingle | Conferences Perrella, Sabrina Integration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3 |
title | Integration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3 |
title_full | Integration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3 |
title_fullStr | Integration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3 |
title_full_unstemmed | Integration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3 |
title_short | Integration and commissioning of the ATLAS Muon-to-Central-Trigger-Processor Interface for Run-3 |
title_sort | integration and commissioning of the atlas muon-to-central-trigger-processor interface for run-3 |
topic | Conferences |
url | http://cds.cern.ch/record/2782406 |
work_keys_str_mv | AT perrellasabrina integrationandcommissioningoftheatlasmuontocentraltriggerprocessorinterfaceforrun3 AT perrellasabrina twepp2021topicalworkshoponelectronicsforparticlephysics |